Your browser doesn't support javascript.
loading
Development of kit formulations for (99m) TcN-MPO: a cationic radiotracer for myocardial perfusion imaging.
Zheng, Yumin; Ji, Shundong; Tomaselli, Elena; Liu, Shuang.
Afiliação
  • Zheng Y; School of Health Sciences, Purdue University, West Lafayette, IN, 47907, USA; Department of Nuclear Medicine, China-Japan Friendship Hospital, Beijing, 100029, China.
J Labelled Comp Radiopharm ; 57(9): 584-92, 2014 Jul.
Article em En | MEDLINE | ID: mdl-25070025
ABSTRACT
The objective of this study was to develop a kit formulation for [(99m) TcN(mpo)(PNP5)](+) (MPO = 2-mercaptopyridine oxide), ((99m) TcN-MPO) to support its clinical evaluations as a SPECT radiotracer. Radiolabeling studies were performed using three different formulations (two-vial formulation and single-vial formulations with/without SnCl2 ) to explore the factors influencing radiochemical purity (RCP) of (99m) TcN-MPO. We found that the most important factor affecting the RCP of (99m) TcN-MPO was the purity of PNP5. (99m) TcN-MPO was prepared >98% RCP (n = 20) using the two-vial formulation. For single-vial formulations with/without SnCl2 , ß-cyclodextrin (ß-CD) is particularly useful as a stabilizer for PNP5. The RCP of (99m) TcN-MPO was 95-98% using ß-CD, but its RCP was only 90-93% with γ-cyclodextrin (γ-CD). It seems that PNP5 fits better into the inner cavity of ß-CD, which forms more stable inclusion complex than γ-CD in the single-vial formulations. The results from biodistribution and imaging studies in Sprague-Dawley rats clearly demonstrated biological equivalence of three different formulations. Single photon-emission computed tomography data suggested that high quality images could be obtained at 0-30-min post-injection without significant interference from the liver radioactivity. Considering the ease for (99m) Tc-labeling and high RCP of (99m) TcN-MPO, the non-SnCl2 single-vial formulation is an attractive choice for future clinical studies.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Kit de Reagentes para Diagnóstico / Compostos de Organotecnécio / Compostos Radiofarmacêuticos Limite: Animals Idioma: En Revista: J Labelled Comp Radiopharm Ano de publicação: 2014 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Kit de Reagentes para Diagnóstico / Compostos de Organotecnécio / Compostos Radiofarmacêuticos Limite: Animals Idioma: En Revista: J Labelled Comp Radiopharm Ano de publicação: 2014 Tipo de documento: Article País de afiliação: China