Your browser doesn't support javascript.
loading
Influence of cyclopentolate hydrochloride on corneal biomechanical properties in healthy individuals.
Oltulu, Refik; Satirtav, Günhal; Kerimoglu, Hürkan; Zengin, Nazmi; Ozkagnici, Ahmet; Okka, Mehmet.
Afiliação
  • Oltulu R; Department of Ophthalmology, Necmettin Erbakan University School of Medicine, Konya, Turkey.
Eye Contact Lens ; 40(5): 309-11, 2014 Sep.
Article em En | MEDLINE | ID: mdl-25083778
ABSTRACT

OBJECTIVE:

This observational study aims to investigate the effects of cyclopentolate hydrochloride (1%) on corneal biomechanical properties, with the ocular response analyzer (ORA), in healthy individuals.

METHODS:

Corneal hysteresis (CH), corneal resistance factor (CRF), Goldmann-correlated intraocular pressure (IOPg), and corneal-compensated intraocular pressure (IOPcc) measurements of 36 (15 female and 21 male) healthy individuals, before and after 45 min of 1% cyclopentolate hydrochloride instillation, were performed by the ORA.

RESULTS:

The mean CH and IOPcc measurements of the eyes were 10.63±1.17 mm Hg and 15.15±2.69 mm Hg, precycloplegia, and 11.09±1.32 mm Hg and 14.16±2.77 mm Hg, postcycloplegia, respectively. The differences between the precycloplegia and postcycloplegia in both measurements were statistically significant (P=0.031, P=0.016, respectively; paired t test). The mean CRF and mean IOPg measurements of the eyes were 10.40±1.16 mm Hg and 14.83±2.56 mm Hg, precycloplegia, and 10.61±1.33 mm Hg and 14.25±2.65 mm Hg, postcycloplegia, respectively. The differences between the precycloplegia and postcycloplegia measurements of the eyes were insignificant (P=0.264 and P=0.100, respectively; paired t test).

CONCLUSIONS:

A 1% cyclopentolate hydrochloride instillation leads to significant changes in the CH values and IOPcc measurements. This should be taken into account during the evaluation of refractive surgery candidates and in clinical conditions where ORA measurements are considered in the diagnosis and follow-up.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Córnea / Ciclopentolato / Midriáticos Tipo de estudo: Observational_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Eye Contact Lens Assunto da revista: OFTALMOLOGIA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Turquia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Córnea / Ciclopentolato / Midriáticos Tipo de estudo: Observational_studies Limite: Adolescent / Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Eye Contact Lens Assunto da revista: OFTALMOLOGIA Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Turquia