Your browser doesn't support javascript.
loading
Simple semi-automated portable capillary electrophoresis instrument with contactless conductivity detection for the determination of ß-agonists in pharmaceutical and pig-feed samples.
Nguyen, Thi Anh Huong; Pham, Thi Ngoc Mai; Doan, Thi Tuoi; Ta, Thi Thao; Sáiz, Jorge; Nguyen, Thi Quynh Hoa; Hauser, Peter C; Mai, Thanh Duc.
Afiliação
  • Nguyen TA; Department of Analytical Chemistry, Faculty of Chemistry, Hanoi University of Science, Vietnam National University, Hanoi - 19 Le Thanh Tong, Hanoi, Viet Nam.
  • Pham TN; Department of Analytical Chemistry, Faculty of Chemistry, Hanoi University of Science, Vietnam National University, Hanoi - 19 Le Thanh Tong, Hanoi, Viet Nam.
  • Doan TT; Department of Analytical Chemistry, Faculty of Chemistry, Hanoi University of Science, Vietnam National University, Hanoi - 19 Le Thanh Tong, Hanoi, Viet Nam.
  • Ta TT; Department of Analytical Chemistry, Faculty of Chemistry, Hanoi University of Science, Vietnam National University, Hanoi - 19 Le Thanh Tong, Hanoi, Viet Nam.
  • Sáiz J; Department of Analytical Chemistry, Physical Chemistry and Chemical Engeneering, University of Alcalá, Ctra, Madrid-Barcelona km 33.6, Alcalá de Henares, Madrid, Spain.
  • Nguyen TQ; Department of Analytical Chemistry, Faculty of Chemistry, Hanoi University of Science, Vietnam National University, Hanoi - 19 Le Thanh Tong, Hanoi, Viet Nam.
  • Hauser PC; University of Basel, Department of Chemistry, Spitalstrasse 51, 4056 Basel, Switzerland. Electronic address: Peter.Hauser@unibas.ch.
  • Mai TD; University of Basel, Department of Chemistry, Spitalstrasse 51, 4056 Basel, Switzerland; Centre for Environmental Technology and Sustainable Development (CETASD), Hanoi University of Science, Nguyen Trai Street 334, Hanoi, Viet Nam. Electronic address: maithanhduc83@gmail.com.
J Chromatogr A ; 1360: 305-11, 2014 Sep 19.
Article em En | MEDLINE | ID: mdl-25115456
ABSTRACT
An inexpensive, robust and easy to use portable capillary electrophoresis instrument with miniaturized high-voltage capacitively coupled contactless conductivity detection was developed. The system utilizes pneumatic operation to manipulate the solutions for all flushing steps. The different operations, i.e. capillary flushing, interface rinsing, and electrophoretic separation, are easily activated by turning an electronic switch. To allow the analysis of samples with limited available volume, and to render the construction less complicated compared to a computer-controlled counterpart, sample injection is carried out hydrodynamically directly from the sample vial into the capillary by manual syphoning. The system is a well performing solution where the financial means for the highly expensive commercial instruments are not available and where the in-house construction of a sophisticated automated instrument is not possible due to limited mechanical and electronic workshop facilities and software programming expertise. For demonstration, the system was employed successfully for the determination of some ß-agonists, namely salbutamol, metoprolol and ractopamine down to 0.7ppm in pharmaceutical and pig-feed sample matrices in Vietnam.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Agonistas Adrenérgicos beta / Eletroforese Capilar / Automação Laboratorial / Ração Animal Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: J Chromatogr A Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Agonistas Adrenérgicos beta / Eletroforese Capilar / Automação Laboratorial / Ração Animal Tipo de estudo: Diagnostic_studies Limite: Animals Idioma: En Revista: J Chromatogr A Ano de publicação: 2014 Tipo de documento: Article