Multimodal functional and anatomic imaging identifies preclinical microvascular abnormalities in type 1 diabetes mellitus.
Lockhart, C J; McCann, A J; Pinnock, R A; Hamilton, P K; Harbinson, M T; McVeigh, G E.
Afiliação
  • Lockhart CJ; Centre for Experimental Medicine, Queen's University Belfast, Belfast, Northern Ireland; and.
  • McCann AJ; Regional Medical Physics Service, Northern Ireland, Royal Victoria Hospital, Belfast, Northern Ireland.
  • Pinnock RA; Regional Medical Physics Service, Northern Ireland, Royal Victoria Hospital, Belfast, Northern Ireland.
  • Hamilton PK; Centre for Experimental Medicine, Queen's University Belfast, Belfast, Northern Ireland; and.
  • Harbinson MT; Centre for Experimental Medicine, Queen's University Belfast, Belfast, Northern Ireland; and.
  • McVeigh GE; Centre for Experimental Medicine, Queen's University Belfast, Belfast, Northern Ireland; and g.mcveigh@qub.ac.uk.
Am J Physiol Heart Circ Physiol ; 307(12): H1729-36, 2014 Dec 15.
Article em En | MEDLINE | ID: mdl-25281566
ABSTRACT
Structural and functional changes in the microcirculation in type 1 diabetes mellitus predict future end-organ damage and macrovascular events. We explored the utility of novel signal processing techniques to detect and track changes in ocular hemodynamics in patients with this disease. Twenty-four patients with uncomplicated type 1 diabetes mellitus and eighteen age- and sex-matched control subjects were studied. Doppler ultrasound was used to interrogate the carotid and ophthalmic arteries, and digital photography was used to image the retinal vasculature. Frequency analysis algorithms were applied to quantify velocity waveform structure and retinal photographic data at baseline and after inhalation of 100% O2. Frequency data were compared between groups. No significant differences were found in the resistive index between groups at baseline or after inhaled O2. Frequency analysis of Doppler flow velocity waveforms identified significant differences in bands 3-7 between patients and control subjects in data captured from the ophthalmic artery (P < 0.01 for each band). In response to inhaled O2, changes in frequency band amplitudes were significantly greater in control subjects compared with patients (P < 0.05). Only control subjects demonstrated a positive correlation (R = 0.61) between changes in retinal vessel diameter and frequency band amplitudes derived from ophthalmic artery waveform data. The use of multimodal signal processing techniques applied to Doppler flow velocity waveforms and retinal photographic data identified preclinical changes in the ocular microcirculation in patients with uncomplicated diabetes mellitus. An impaired autoregulatory response of the retinal microvasculature may contribute to the future development of retinopathy in such patients.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Ultrassonografia Doppler / Diabetes Mellitus Tipo 1 / Microvasos Tipo de estudo: Evaluation_studies / Observational_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Am J Physiol Heart Circ Physiol Assunto da revista: CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Processamento de Imagem Assistida por Computador / Ultrassonografia Doppler / Diabetes Mellitus Tipo 1 / Microvasos Tipo de estudo: Evaluation_studies / Observational_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: Am J Physiol Heart Circ Physiol Assunto da revista: CARDIOLOGIA / FISIOLOGIA Ano de publicação: 2014 Tipo de documento: Article