Your browser doesn't support javascript.
loading
Left ventricular torsion shear angle volume analysis in patients with hypertension: a global approach for LV diastolic function.
J Cardiovasc Magn Reson ; 16: 70, 2014 Sep 26.
Article em En | MEDLINE | ID: mdl-25316384
ABSTRACT

BACKGROUND:

Torsion shear angle φ is an important measure of left ventricular (LV) systolic and diastolic functions. Here we provide a novel index utilizing LV normalized torsion shear angle φ ^ volume V ^ loop to assess LV diastolic functional properties. We defined the area within φ ^ V ^ loop as torsion hysteresis area, and hypothesized that it may be an important global parameter of diastolic function. We evaluated the φ ^ changes to increased V ^ during early diastole - d φ ^ / d V ^ as a potential measure of LV suction.

METHODS:

Sixty resistant hypertension patients (HTN), forty control volunteers were studied using cardiovascular magnetic resonance with tissue tagging. Volumetric and torsional parameters were evaluated.

RESULTS:

HTN demonstrated concentric remodeling with preserved ejection fraction. HTN had significantly decreased normalized early filling rate, early diastolic mitral annulus velocity and E/A (1.33 ± 1.13 vs. 2.19 ± 1.07, P < 0.0001) vs. control. Torsion hysteresis area was greater (0.11 ± 0.07 vs. 0.079 ± 0.045, P < 0.001) and peak - d φ ^ / d V ^ at early diastole was higher (10.46 ± 8.51 vs. 6.29 ± 3.85, P = 0.002) than control. Torsion hysteresis area was significantly correlated with E/A (r = -0.23, P = 0.025). Thirteen HTN patients had both E/A ratio < 1.12 (Control mean E/A-1SD) and torsion hysteresis area > 0.12 (Control mean torsion hysteresis area + 1SD).

CONCLUSIONS:

Torsion hysteresis area and peak early diastolic - d φ ^ / d V ^ were significantly increased in hypertensive concentric remodeling. The φ ^ V ^ loop takes into account the active and passive recoil processes of LV diastolic and systolic phases, therefore provides a new global description of LV diastolic function.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Função Ventricular Esquerda / Disfunção Ventricular Esquerda / Imagem Cinética por Ressonância Magnética / Diástole / Hipertensão Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Magn Reson Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2014 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Função Ventricular Esquerda / Disfunção Ventricular Esquerda / Imagem Cinética por Ressonância Magnética / Diástole / Hipertensão Tipo de estudo: Etiology_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Cardiovasc Magn Reson Assunto da revista: ANGIOLOGIA / CARDIOLOGIA / DIAGNOSTICO POR IMAGEM Ano de publicação: 2014 Tipo de documento: Article