Your browser doesn't support javascript.
loading
Establishment of diagnostic reference levels in cardiac CT in France: a need for patient dose optimisation.
Mafalanka, F; Etard, C; Rehel, J L; Pesenti-Rossi, D; Amrar-Vennier, F; Baron, N; Christiaens, L; Convers-Domart, R; Defez, D; Douek, P; Gaxotte, V; Georges, J L; Leygnac, S; Ou, P; Sablayrolles, J L; Salvat, C; Schouman-Claeys, E; Sirol, M; Aubert, B.
Afiliação
  • Mafalanka F; Institut de Radioprotection et de Sureté Nucléaire, PRP-HOM/SER, BP17, Fontenay-aux-Roses 92262, France.
  • Etard C; Institut de Radioprotection et de Sureté Nucléaire, PRP-HOM/SER, BP17, Fontenay-aux-Roses 92262, France cecile.etard@irsn.fr.
  • Rehel JL; Institut de Radioprotection et de Sureté Nucléaire, PRP-HOM/SER, BP17, Fontenay-aux-Roses 92262, France.
  • Pesenti-Rossi D; Clinique Ambroise Paré, Neuilly-sur-Seine, France.
  • Amrar-Vennier F; Hôpital Sud-Francilien, Corbeil-Essonnes, France.
  • Baron N; Hôpital Mignot, Le Chesnay, France.
  • Christiaens L; Centre Hospitalier Universitaire, Poitiers, France.
  • Convers-Domart R; Hôpital Mignot, Le Chesnay, France.
  • Defez D; Centre Hospitalier Universitaire, Lyon, France.
  • Douek P; Centre Hospitalier Universitaire, Lyon, France.
  • Gaxotte V; Hôpital Bichat, AP-HP, Paris, France.
  • Georges JL; Hôpital Mignot, Le Chesnay, France.
  • Leygnac S; Hôpital Bichat, AP-HP, Paris, France.
  • Ou P; Hôpital Bichat, AP-HP, Paris, France.
  • Sablayrolles JL; Centre de Cardiologie du Nord, Saint-Denis, France.
  • Salvat C; Hôpital Lariboisière, AP-HP, Paris, France.
  • Schouman-Claeys E; Hôpital Bichat, AP-HP, Paris, France.
  • Sirol M; Hôpital Lariboisière, AP-HP, Paris, France.
  • Aubert B; Institut de Radioprotection et de Sureté Nucléaire, PRP-HOM/SER, BP17, Fontenay-aux-Roses 92262, France.
Radiat Prot Dosimetry ; 164(1-2): 116-9, 2015 Apr.
Article em En | MEDLINE | ID: mdl-25342609
ABSTRACT
The objective of this study was to propose diagnostic reference levels (DRLs) for coronary computed tomography angiography (CCTA), in the context of a large variability in patient radiation dose, and the lack of European recommendations. Volume Computed Tomography Dose Index (CTDIvol) and dose-length product (DLP) were collected from 460 CCTAs performed over a 3-month period at eight French hospitals. CCTAs (∼50 per centre) were performed using the routine protocols of the centres, and 64- to 320-detector CT scanners. ECG gating was prospective (n = 199) or retrospective (n = 261). The large gap in dose between these two modes required to propose specific DRLs 26 and 44 mGy for CTDIvol, and 370 and 970 mGy cm for DLP, respectively. This study confirms the large variability in patient doses during CCTA and underlines the need for the optimisation of cardiac acquisition protocols. Availability of national DRLs should be mandatory in this setting.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiometria / Tomografia Computadorizada por Raios X / Angiografia Coronária Tipo de estudo: Diagnostic_studies / Guideline Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2015 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Radiometria / Tomografia Computadorizada por Raios X / Angiografia Coronária Tipo de estudo: Diagnostic_studies / Guideline Idioma: En Revista: Radiat Prot Dosimetry Ano de publicação: 2015 Tipo de documento: Article País de afiliação: França