Your browser doesn't support javascript.
loading
Electrochemical investigation of the interaction between topotecan and DNA at disposable graphite electrodes.
Congur, Gulsah; Erdem, Arzum; Mese, Fehmi.
Afiliação
  • Congur G; Ege University, Faculty of Pharmacy, Analytical Chemistry Department, 35100 Bornova, Izmir, Turkey.
  • Erdem A; Ege University, Faculty of Pharmacy, Analytical Chemistry Department, 35100 Bornova, Izmir, Turkey. Electronic address: arzum.erdem@ege.edu.tr.
  • Mese F; Ege University, Faculty of Pharmacy, Analytical Chemistry Department, 35100 Bornova, Izmir, Turkey.
Bioelectrochemistry ; 102: 21-8, 2015 Apr.
Article em En | MEDLINE | ID: mdl-25461757
ABSTRACT
Topotecan (TPT) is a semisynthetic, water soluble analog of the plant alkaloid camptothecin which has been widely used for the treatment of ovarian and cervical cancers. To obtain better understanding on how it can affect DNA structure, electrochemical biosensor platforms for the investigation of TPT-double stranded DNA (dsDNA) interaction were developed for the first time in this study. The electrochemical detection of TPT, and TPT-dsDNA interaction were investigated at the surface of pencil graphite electrodes (PGEs) and single-walled carbon nanotube (SWCNT) modified PGEs by using differential pulse voltammetry (DPV). The changes at the oxidation signals of TPT and guanine were evaluated before/after each modification/immobilization step. An enhanced sensor response was obtained by using SWCNT-PGEs compared to unmodified PGEs with resulting limits of detection (LODs) for TPT as 0.51 µg/mL, 0.45 µg/mL, 0.37 µg/mL (130 pmol, 117 pmol, 96.5 pmol in a 110 µL sample, respectively) by using electrochemically pretreated PGE, unmodified PGE and SWCNT modified PGE. In addition, electrochemical impedance spectroscopy (EIS) measurements were performed for the purpose of modification of PGEs by using SWCNTs and the interaction process at the surface of SWCNT-PGEs by evaluating the changes at the charge transfer resistance (Rct).
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: DNA / Técnicas Biossensoriais / Topotecan / Grafite / Antineoplásicos Idioma: En Revista: Bioelectrochemistry Assunto da revista: BIOQUIMICA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Turquia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: DNA / Técnicas Biossensoriais / Topotecan / Grafite / Antineoplásicos Idioma: En Revista: Bioelectrochemistry Assunto da revista: BIOQUIMICA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Turquia