Your browser doesn't support javascript.
loading
Alkaline conditions in hydrophilic interaction liquid chromatography for intracellular metabolite quantification using tandem mass spectrometry.
Teleki, Attila; Sánchez-Kopper, Andrés; Takors, Ralf.
Afiliação
  • Teleki A; Institute of Biochemical Engineering, University of Stuttgart, 70569 Stuttgart, Germany.
  • Sánchez-Kopper A; Institute of Biochemical Engineering, University of Stuttgart, 70569 Stuttgart, Germany.
  • Takors R; Institute of Biochemical Engineering, University of Stuttgart, 70569 Stuttgart, Germany. Electronic address: ralf.takors@ibvt.uni-stuttgart.de.
Anal Biochem ; 475: 4-13, 2015 Apr 15.
Article em En | MEDLINE | ID: mdl-25600449
ABSTRACT
Modeling of metabolic networks as part of systems metabolic engineering requires reliable quantitative experimental data of intracellular concentrations. The hydrophilic interaction liquid chromatography-electrospray ionization-tandem mass spectrometry (HILIC-ESI-MS/MS) method was used for quantitative profiling of more than 50 hydrophilic key metabolites of cellular metabolism. Without prior derivatization, sugar phosphates, organic acids, nucleotides, and amino acids were measured under alkaline and acidic mobile phase conditions with pre-optimized multiple reaction monitoring (MRM) transitions. Irrespective of the polarity mode of the acquisition method used, alkaline conditions achieved the best quantification limits and linear dynamic ranges. Fully 90% of the analyzed metabolites presented detection limits better than 0.5pmol (on column), and 70% presented 1.5-fold higher signal intensities under alkaline mobile phase conditions. The quality of the method was further demonstrated by absolute quantification of selected metabolites in intracellular extracts of Escherichia coli. In addition, quantification bias caused by matrix effects was investigated by comparison of calibration strategies standard-based external calibration, isotope dilution, and standard addition with internal standards. Here, we recommend the use of alkaline mobile phase with polymer-based zwitterionic hydrophilic interaction chromatography (ZIC-pHILIC) as the most sensitive scenario for absolute quantification for a broad range of metabolites.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Escherichia coli K12 / Espectrometria de Massas em Tandem Idioma: En Revista: Anal Biochem Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Escherichia coli K12 / Espectrometria de Massas em Tandem Idioma: En Revista: Anal Biochem Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Alemanha