Your browser doesn't support javascript.
loading
Clinical results of an automated artificial pancreas using technosphere inhaled insulin to mimic first-phase insulin secretion.
Zisser, Howard; Dassau, Eyal; Lee, Justin J; Harvey, Rebecca A; Bevier, Wendy; Doyle, Francis J.
Afiliação
  • Zisser H; Sansum Diabetes Research Institute, Santa Barbara, CA, USA Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA, USA hzisser@gmail.com.
  • Dassau E; Sansum Diabetes Research Institute, Santa Barbara, CA, USA Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA, USA Institute for Collaborative Biotechnologies, University of California, Santa Barbara, Santa Barbara, CA, USA.
  • Lee JJ; Sansum Diabetes Research Institute, Santa Barbara, CA, USA Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA, USA.
  • Harvey RA; Sansum Diabetes Research Institute, Santa Barbara, CA, USA Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA, USA.
  • Bevier W; Sansum Diabetes Research Institute, Santa Barbara, CA, USA.
  • Doyle FJ; Sansum Diabetes Research Institute, Santa Barbara, CA, USA Department of Chemical Engineering, University of California, Santa Barbara, Santa Barbara, CA, USA Institute for Collaborative Biotechnologies, University of California, Santa Barbara, Santa Barbara, CA, USA.
J Diabetes Sci Technol ; 9(3): 564-72, 2015 May.
Article em En | MEDLINE | ID: mdl-25901023
OBJECTIVE: The purpose of this study was to investigate whether or not adding a fixed preprandial dose of inhaled insulin to a fully automated closed loop artificial pancreas would improve the postprandial glucose control without adding an increased risk of hypoglycemia. RESEARCH DESIGN AND METHODS: Nine subjects with T1DM were recruited for the study. The patients were on closed-loop control for 24 hours starting around 4:30 pm. Mixed meals (~50 g CHO) were given at 6:30 pm and 7:00 am the following day. For the treatment group each meal was preceded by the inhalation of one 10 U dose of Technosphere Insulin (TI). Subcutaneous insulin delivery was controlled by a zone model predictive control algorithm (zone-MPC). At 11:00 am, the patient exercised for 30 ± 5 minutes at 50% of predicted heart rate reserve. RESULTS: The use of TI resulted in increasing the median percentage time in range (70-180 mg/dl, BG) during the 5-hour postprandial period by 21.6% (81.6% and 60% in the with/without TI cases, respectively, P = .06) and reducing the median postprandial glucose peak by 33 mg/dl (172 mg/dl and 205 mg/dl in the with and without TI cases, respectively, P = .004). The median percentage time in range 80-140 mg/dl during the entire study period was 67.5% as compared to percentage time in range without the use of TI of 55.2% (P = .03). CONCLUSIONS: Adding preprandial TI (See video supplement) to an automated closed-loop AP system resulted in superior postprandial control as demonstrated by lower postprandial glucose exposure without addition hypoglycemia.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pâncreas Artificial / Diabetes Mellitus Tipo 1 / Hipoglicemiantes / Insulina Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Diabetes Sci Technol Assunto da revista: ENDOCRINOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Pâncreas Artificial / Diabetes Mellitus Tipo 1 / Hipoglicemiantes / Insulina Tipo de estudo: Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Diabetes Sci Technol Assunto da revista: ENDOCRINOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Estados Unidos