Your browser doesn't support javascript.
loading
Comparison of clinical performances among Roche Cobas HPV, RFMP HPV PapilloTyper and Hybrid Capture 2 assays for detection of high-risk types of human papillomavirus.
Yu, Shinae; Kwon, Min-Jung; Lee, Eun Hee; Park, Hyosoon; Woo, Hee-Yeon.
Afiliação
  • Yu S; Department of Laboratory Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, South Korea.
  • Kwon MJ; Department of Laboratory Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, South Korea.
  • Lee EH; Green Cross Laboratories, Yongin, South Korea.
  • Park H; Department of Laboratory Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, South Korea.
  • Woo HY; Department of Laboratory Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, South Korea.
J Med Virol ; 87(9): 1587-93, 2015 Sep.
Article em En | MEDLINE | ID: mdl-25914215
ABSTRACT
The cervical cancer screening guidelines suggest that early detection of HPV16 and HPV18 is helpful for identifying women with cervical intraepithelial neoplasia (CIN) grade two or higher. We comparatively evaluated three HPV DNA assays, Roche Cobas HPV, RFMP HPV PapilloTyper, and Hybrid Capture 2 (HC2). A total of 861 cervical swab samples from women over 30 years of age were classified into two groups, that is, high grade squamous intraepithelial lesion (HSIL) and non-HSIL, according to cervical cytology results and analyzed by three assays. The results of direct sequencing or Linear array HPV genotyping test were considered true when the three assays presented discrepancies. The concordance rates between Roche Cobas HPV versus RFMP HPV PapilloTyper, RFMP HPV PapilloTyper versus HC2, and Roche Cobas versus HC2 were 94.5%, 94.3%, and 95.9%, respectively. For detection of HPV16 and HPV18, Roche Cobas HPV showed the concordance rates of 98.3% (κ = 0.73) and 99.4% (κ = 0.40) with the confirmation tests, respectively; and RFMP HPV PapilloTyper showed the concordance rates of 99.5% (κ = 0.92) and 100.0% (κ = 1.00), respectively. In conclusion, Roche Cobas HPV, RFMP HPV PapilloTyper, and HC2 showed high agreement rates. Roche Cobas HPV and RFMP HPV PapilloTyper are particularly useful, since both provide HPV specific genotypes, HPV16 and HPV18.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Papillomaviridae / DNA Viral / Infecções por Papillomavirus / Detecção Precoce de Câncer / Reação em Cadeia da Polimerase em Tempo Real / Testes de DNA para Papilomavírus Humano Tipo de estudo: Diagnostic_studies / Etiology_studies / Evaluation_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: J Med Virol Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Coréia do Sul

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Papillomaviridae / DNA Viral / Infecções por Papillomavirus / Detecção Precoce de Câncer / Reação em Cadeia da Polimerase em Tempo Real / Testes de DNA para Papilomavírus Humano Tipo de estudo: Diagnostic_studies / Etiology_studies / Evaluation_studies / Prognostic_studies / Risk_factors_studies / Screening_studies Limite: Adult / Aged / Female / Humans / Middle aged Idioma: En Revista: J Med Virol Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Coréia do Sul