Your browser doesn't support javascript.
loading
Adding MRI to ultrasound and ultrasound-guided fine-needle aspiration reduces the false-negative rate of axillary lymph node metastasis diagnosis in breast cancer patients.
Hyun, S J; Kim, E-K; Yoon, J H; Moon, H J; Kim, M J.
Afiliação
  • Hyun SJ; Department of Radiology, Breast Cancer Clinic, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Kim EK; Department of Radiology, Breast Cancer Clinic, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Yoon JH; Department of Radiology, Breast Cancer Clinic, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Moon HJ; Department of Radiology, Breast Cancer Clinic, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Republic of Korea.
  • Kim MJ; Department of Radiology, Breast Cancer Clinic, Severance Hospital, Research Institute of Radiological Science, Yonsei University College of Medicine, Seoul, Republic of Korea. Electronic address: mines@yuhs.ac.
Clin Radiol ; 70(7): 716-22, 2015 Jul.
Article em En | MEDLINE | ID: mdl-25917544
AIM: To evaluate whether adding magnetic resonance imaging (MRI) to ultrasound (US) and US-guided fine-needle aspiration (US-FNA) can reduce the false-negative rate (FNR) in the diagnosis of axillary lymph node metastasis (ALNM) in breast cancer patients, and to assess false-negative diagnosis of N2 and N3 disease when adding MRI to US and US-FNA. MATERIALS AND METHODS: From March 2012 to February 2013, 497 breast cancer patients were included in the study. ALNM was evaluated according to US and US-FNA prior to MRI. Second-look US was performed when MRI showed positive findings of ALNM. If second-look US also revealed a positive finding, US-FNA was performed. Diagnostic performance, including FNR, was calculated for US and US-FNA with and without MRI. The negative predictive value (NPV) of N2 and N3 disease was evaluated in negative cases based on US and US-FNA with MRI. RESULTS: A total of 159 of 497 (32.0%) patients were found to have ALNM. Among them, 92 patients were diagnosed with metastasis on US and US-FNA. When adding MRI to US and US-FNA, an additional six patients were diagnosed with metastasis. The FNR of diagnosis of ALNM was improved by the addition of MRI (42.1% versus 38.4%, p = 0.0143). The NPV for N2 and N3 disease was 98% (391/399) based on US and US-FNA with MRI. CONCLUSION: Adding MRI to US and US-FNA could reduce the FNR of the diagnosis of ALNM. Furthermore, US and US-FNA with MRI may exclude 98% of N2 and N3 disease.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Imageamento por Ressonância Magnética / Ultrassonografia de Intervenção / Biópsia de Linfonodo Sentinela / Linfonodos / Metástase Linfática Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Middle aged Idioma: En Revista: Clin Radiol Ano de publicação: 2015 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Neoplasias da Mama / Imageamento por Ressonância Magnética / Ultrassonografia de Intervenção / Biópsia de Linfonodo Sentinela / Linfonodos / Metástase Linfática Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Aged80 / Female / Humans / Middle aged Idioma: En Revista: Clin Radiol Ano de publicação: 2015 Tipo de documento: Article