Your browser doesn't support javascript.
loading
F-EVAR does not Impair Renal Function more than Open Surgery for Juxtarenal Aortic Aneurysms: Single Centre Results.
Shahverdyan, R; Majd, M P; Thul, R; Braun, N; Gawenda, M; Brunkwall, J.
Afiliação
  • Shahverdyan R; Department of Vascular Surgery, University Hospital of Cologne, Cologne, Germany.
  • Majd MP; Department of Vascular Surgery, University Hospital of Cologne, Cologne, Germany.
  • Thul R; Department of Vascular Surgery, University Hospital of Cologne, Cologne, Germany.
  • Braun N; Department of Vascular Surgery, University Hospital of Cologne, Cologne, Germany.
  • Gawenda M; Department of Vascular Surgery, University Hospital of Cologne, Cologne, Germany.
  • Brunkwall J; Department of Vascular Surgery, University Hospital of Cologne, Cologne, Germany. Electronic address: jan.brunkwall@uk-koeln.de.
Eur J Vasc Endovasc Surg ; 50(4): 432-41, 2015 Oct.
Article em En | MEDLINE | ID: mdl-26100450
OBJECTIVE: To compare the results of elective open surgical repair (OSR) and total endovascular repair of juxtarenal aortic aneurysms (JAA), with either the Cook Zenith or the Vascutek Anaconda fenestrated stent grafts (F-EVAR) in a university hospital setting. PATIENTS AND METHODS: Between April 1999 and July 2014, of 926 patients with an abdominal aortic aneurysm, 69 were juxtarenal, where 34 had an elective OSR and 35 had F-EVAR. A post-operative rise of baseline creatinine by >50% and/or deterioration of estimated glomerular filtration rate by 25% were defined as renal failure. RESULTS: The demographics of the patients were similar except for heart insufficiency, peripheral arterial disease, and pre-existing renal artery stenosis (p < .05). Median aneurysm diameters were 57 mm (range 50-80 mm) and 56 mm (range 36-64 mm) (p = .194), respectively, and the median pre-operative serum creatinine levels were 94 µmol/L (range 65-286 µmol/L) and 96 µmol/L (range 57-333 µmol/L) (p = .871) with median estimated glomerular filtration rate of 68 mL/min (range 21-117 mL/min) and 70 mL/min (range 18-114 mL/min) (p = .308) in the open and endovascular groups, respectively. The technical success (OSR versus F-EVAR) was 100% versus 94.3% with complete exclusion of the aneurysms in all cases. Median procedure time was 171 versus 188 min. During median in hospital stay of 11 versus 7 days (p = .05), mortality was 0 versus 2.9% and new onset of post-operative renal insufficiency was detected in 26.5% versus 8.5% patients (p = .05), although with 11.8% versus 5.7% being persistent (p = .428). During follow up, statistically similar new (late or persistent post-operative) renal insufficiency was detected in 14.7% versus 8.8% with dialysis in 3% of patients in each group with similar mortality within the 24 months. CONCLUSIONS: This retrospective analysis demonstrates that OSR might be combined with more acute post-operative renal impairment than F-EVAR for JAA, but with similar intermediate term procedure related mortality and renal outcomes.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma da Aorta Abdominal / Implante de Prótese Vascular / Insuficiência Renal / Procedimentos Endovasculares Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Aged80 País/Região como assunto: Europa Idioma: En Revista: Eur J Vasc Endovasc Surg Assunto da revista: ANGIOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aneurisma da Aorta Abdominal / Implante de Prótese Vascular / Insuficiência Renal / Procedimentos Endovasculares Tipo de estudo: Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Limite: Aged80 País/Região como assunto: Europa Idioma: En Revista: Eur J Vasc Endovasc Surg Assunto da revista: ANGIOLOGIA Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Alemanha