Your browser doesn't support javascript.
loading
Development of a rapid and sensitive one-step reverse transcription-nested polymerase chain reaction in a single tube using the droplet-polymerase chain reaction machine.
Yamaguchi, Akemi; Matsuda, Kazuyuki; Sueki, Akane; Taira, Chiaki; Uehara, Masayuki; Saito, Yasunori; Honda, Takayuki.
Afiliação
  • Yamaguchi A; Graduate School of Science and Technology, Shinshu University, Nagano, Japan; Core Technology Development Center, Seiko Epson Corporation, Suwa, Japan.
  • Matsuda K; Department of Laboratory Medicine, Shinshu University Hospital, Matsumoto, Japan. Electronic address: kmatsuda@shinshu-u.ac.jp.
  • Sueki A; Department of Laboratory Medicine, Shinshu University Hospital, Matsumoto, Japan.
  • Taira C; Department of Laboratory Medicine, Shinshu University Hospital, Matsumoto, Japan.
  • Uehara M; Core Technology Development Center, Seiko Epson Corporation, Suwa, Japan.
  • Saito Y; Institute of Engineering, Academic Assembly, Shinshu University, Nagano, Japan.
  • Honda T; Department of Laboratory Medicine, Shinshu University Hospital, Matsumoto, Japan.
Clin Chim Acta ; 448: 150-4, 2015 Aug 25.
Article em En | MEDLINE | ID: mdl-26148723
BACKGROUND: Reverse transcription (RT)-nested polymerase chain reaction (PCR) is a time-consuming procedure because it has several handling steps and is associated with the risk of cross-contamination during each step. Therefore, a rapid and sensitive one-step RT-nested PCR was developed that could be performed in a single tube using a droplet-PCR machine. METHODS: The K562 BCR-ABL mRNA-positive cell line as well as bone marrow aspirates from 5 patients with chronic myelogenous leukemia (CML) and 5 controls without CML were used. We evaluated one-step RT-nested PCR using the droplet-PCR machine. RESULTS: One-step RT-nested PCR performed in a single tube using the droplet-PCR machine enabled the detection of BCR-ABL mRNA within 40min, which was 10(3)-fold superior to conventional RT nested PCR using three steps in separate tubes. The sensitivity of the one-step RT-nested PCR was 0.001%, with sample reactivity comparable to that of the conventional assay. CONCLUSIONS: One-step RT-nested PCR was developed using the droplet-PCR machine, which enabled all reactions to be performed in a single tube accurately and rapidly and with high sensitivity. This one-step RT-nested PCR may be applicable to a wide spectrum of genetic tests in clinical laboratories.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reação em Cadeia da Polimerase Via Transcriptase Reversa Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Clin Chim Acta Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Japão

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Reação em Cadeia da Polimerase Via Transcriptase Reversa Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Clin Chim Acta Ano de publicação: 2015 Tipo de documento: Article País de afiliação: Japão