Your browser doesn't support javascript.
loading
"Planned" permanent pacemaker implantation in one-day-old newborn after prenatal diagnosis of congenital complete atrioventricular heart block.
Haponiuk, Ireneusz; Chojnicki, Maciej; Szofer-Sendrowska, Aneta; Juscinski, Jacek; Steffens, Mariusz; Jaworski, Radoslaw; Domzalska-Popadiuk, Iwona; Gierat-Haponiuk, Katarzyna; Leszczynska, Katarzyna; Preis, Krzysztof.
Afiliação
  • Haponiuk I; Department of Pediatric Cardiac Surgery, Mikolaj Kopernik Hospital in Gdansk, Poland ; Chair of Physiotherapy, Gdansk University of Physical Education and Sport, Poland.
  • Chojnicki M; Department of Pediatric Cardiac Surgery, Mikolaj Kopernik Hospital in Gdansk, Poland.
  • Szofer-Sendrowska A; Department of Pediatric Cardiac Surgery, Mikolaj Kopernik Hospital in Gdansk, Poland.
  • Juscinski J; Department of Pediatric Cardiac Surgery, Mikolaj Kopernik Hospital in Gdansk, Poland.
  • Steffens M; Department of Pediatric Cardiac Surgery, Mikolaj Kopernik Hospital in Gdansk, Poland.
  • Jaworski R; Department of Pediatric Cardiac Surgery, Mikolaj Kopernik Hospital in Gdansk, Poland.
  • Domzalska-Popadiuk I; Department of Neonatal Intensive Care, Medical University of Gdansk, Poland.
  • Gierat-Haponiuk K; Department of Rehabilitation, Medical University of Gdansk, Poland.
  • Leszczynska K; Department of Gynecology, Medical University of Gdansk, Poland.
  • Preis K; Department of Gynecology, Medical University of Gdansk, Poland.
Kardiochir Torakochirurgia Pol ; 11(1): 76-8, 2014 Mar.
Article em En | MEDLINE | ID: mdl-26336400
We present a case of a severely ill newborn with congenital atrioventricular heart block (CAVB) diagnosed prenatally. The initial drug therapy just after birth was ineffective, the heart rhythm remained 54 beats per minute, and control echocardiographies showed forthcoming decrease of the left ventricular function with mitral insufficiency. A permanent pacing system with bipolar electrodes eluting two steroids (Medtronic Capsule, Medtronic Inc. Minneapolis, USA) and Medtronic ADAPTA(®) pulse generator (Medtronic Inc, Minneapolis, USA) was implanted on the first day of life. The pace control as well as wound healing were uncomplicated, and the baby was discharged home without additional medication. The procedure of permanent pacemaker implantation on the first day of life was safe and effective, as a benefit from a successfully performed prenatal program in our cooperating institutions.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Kardiochir Torakochirurgia Pol Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Polônia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Kardiochir Torakochirurgia Pol Ano de publicação: 2014 Tipo de documento: Article País de afiliação: Polônia