Your browser doesn't support javascript.
loading
Lack of correlation between reaction speed and analytical sensitivity in isothermal amplification reveals the value of digital methods for optimization: validation using digital real-time RT-LAMP.
Khorosheva, Eugenia M; Karymov, Mikhail A; Selck, David A; Ismagilov, Rustem F.
Afiliação
  • Khorosheva EM; Division of Chemistry and Chemical Engineering, California Institute of Technology, 1200 East California Blvd., Pasadena, CA 91125, USA.
  • Karymov MA; Division of Chemistry and Chemical Engineering, California Institute of Technology, 1200 East California Blvd., Pasadena, CA 91125, USA.
  • Selck DA; Division of Chemistry and Chemical Engineering, California Institute of Technology, 1200 East California Blvd., Pasadena, CA 91125, USA.
  • Ismagilov RF; Division of Chemistry and Chemical Engineering, California Institute of Technology, 1200 East California Blvd., Pasadena, CA 91125, USA rustem.admin@caltech.edu.
Nucleic Acids Res ; 44(2): e10, 2016 Jan 29.
Article em En | MEDLINE | ID: mdl-26358811
In this paper, we asked if it is possible to identify the best primers and reaction conditions based on improvements in reaction speed when optimizing isothermal reactions. We used digital single-molecule, real-time analyses of both speed and efficiency of isothermal amplification reactions, which revealed that improvements in the speed of isothermal amplification reactions did not always correlate with improvements in digital efficiency (the fraction of molecules that amplify) or with analytical sensitivity. However, we observed that the speeds of amplification for single-molecule (in a digital device) and multi-molecule (e.g. in a PCR well plate) formats always correlated for the same conditions. Also, digital efficiency correlated with the analytical sensitivity of the same reaction performed in a multi-molecule format. Our finding was supported experimentally with examples of primer design, the use or exclusion of loop primers in different combinations, and the use of different enzyme mixtures in one-step reverse-transcription loop-mediated amplification (RT-LAMP). Our results show that measuring the digital efficiency of amplification of single-template molecules allows quick, reliable comparisons of the analytical sensitivity of reactions under any two tested conditions, independent of the speeds of the isothermal amplification reactions.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: RNA Viral / Primers do DNA / Reação em Cadeia da Polimerase Via Transcriptase Reversa / Reação em Cadeia da Polimerase em Tempo Real Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Nucleic Acids Res Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: RNA Viral / Primers do DNA / Reação em Cadeia da Polimerase Via Transcriptase Reversa / Reação em Cadeia da Polimerase em Tempo Real Tipo de estudo: Diagnostic_studies / Prognostic_studies Idioma: En Revista: Nucleic Acids Res Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Estados Unidos