Mini-arteriotomy to remove misplaced Gugliemi detachable coils: case report and technical note.
Jin, Guo-Liang; Yuan, Zi-Gang.
Afiliação
  • Jin GL; Department of Neurosurgery, Shaoxing People's Hospital, Shaoxing Hospital of Zhejiang University China.
  • Yuan ZG; Department of Neurosurgery, Shaoxing People's Hospital, Shaoxing Hospital of Zhejiang University China.
Int J Clin Exp Med ; 8(9): 16772-7, 2015.
Article em En | MEDLINE | ID: mdl-26629219
ABSTRACT
Coil-related thromboembolic complications due to misplacement of coils in embolization of the intracranial aneurysms might result in severe neurological deficits. We describe an unusual case of a ruptured posterior communicating artery (PcomA) aneurysm in a woman who underwent a Mini-Arteriotomy to rescue error embolism in the left middle cerebral artery (MCA). This surgical procedure might be considered as an alternative route in selected patients with coil-related thromboembolic complications. This novel technology gives us a simple and practical method to remedy the misplacement of coils in a wide region of the cerebral vascular after interventional treatment.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: Int J Clin Exp Med Ano de publicação: 2015 Tipo de documento: Article