Your browser doesn't support javascript.
loading
Accuracy of machine learning classifiers using bilateral data from a Scheimpflug camera for identifying eyes with preclinical signs of keratoconus.
Kovács, Illés; Miháltz, Kata; Kránitz, Kinga; Juhász, Éva; Takács, Ágnes; Dienes, Lóránt; Gergely, Róbert; Nagy, Zoltán Z.
Afiliação
  • Kovács I; From the Department of Ophthalmology (Kovács, Kránitz, Juhász, Takács, Dienes, Gergely, Nagy), Semmelweis University, Budapest, Hungary; the Karl Landsteiner Institute of Process Optimization and QM in Cataract Surgery (Mihált), Vienna, Austria. Electronic address: kovacs.illes@med.semmelweis-univ.h
  • Miháltz K; From the Department of Ophthalmology (Kovács, Kránitz, Juhász, Takács, Dienes, Gergely, Nagy), Semmelweis University, Budapest, Hungary; the Karl Landsteiner Institute of Process Optimization and QM in Cataract Surgery (Mihált), Vienna, Austria.
  • Kránitz K; From the Department of Ophthalmology (Kovács, Kránitz, Juhász, Takács, Dienes, Gergely, Nagy), Semmelweis University, Budapest, Hungary; the Karl Landsteiner Institute of Process Optimization and QM in Cataract Surgery (Mihált), Vienna, Austria.
  • Juhász É; From the Department of Ophthalmology (Kovács, Kránitz, Juhász, Takács, Dienes, Gergely, Nagy), Semmelweis University, Budapest, Hungary; the Karl Landsteiner Institute of Process Optimization and QM in Cataract Surgery (Mihált), Vienna, Austria.
  • Takács Á; From the Department of Ophthalmology (Kovács, Kránitz, Juhász, Takács, Dienes, Gergely, Nagy), Semmelweis University, Budapest, Hungary; the Karl Landsteiner Institute of Process Optimization and QM in Cataract Surgery (Mihált), Vienna, Austria.
  • Dienes L; From the Department of Ophthalmology (Kovács, Kránitz, Juhász, Takács, Dienes, Gergely, Nagy), Semmelweis University, Budapest, Hungary; the Karl Landsteiner Institute of Process Optimization and QM in Cataract Surgery (Mihált), Vienna, Austria.
  • Gergely R; From the Department of Ophthalmology (Kovács, Kránitz, Juhász, Takács, Dienes, Gergely, Nagy), Semmelweis University, Budapest, Hungary; the Karl Landsteiner Institute of Process Optimization and QM in Cataract Surgery (Mihált), Vienna, Austria.
  • Nagy ZZ; From the Department of Ophthalmology (Kovács, Kránitz, Juhász, Takács, Dienes, Gergely, Nagy), Semmelweis University, Budapest, Hungary; the Karl Landsteiner Institute of Process Optimization and QM in Cataract Surgery (Mihált), Vienna, Austria.
J Cataract Refract Surg ; 42(2): 275-83, 2016 Feb.
Article em En | MEDLINE | ID: mdl-27026453

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fotografação / Córnea / Técnicas de Diagnóstico Oftalmológico / Aprendizado de Máquina / Ceratocone Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Cataract Refract Surg Assunto da revista: OFTALMOLOGIA Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fotografação / Córnea / Técnicas de Diagnóstico Oftalmológico / Aprendizado de Máquina / Ceratocone Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Adult / Female / Humans / Male / Middle aged Idioma: En Revista: J Cataract Refract Surg Assunto da revista: OFTALMOLOGIA Ano de publicação: 2016 Tipo de documento: Article