Albumin-glutaraldehyde glue for repair of superficial lung defect: an in vitro experiment.
Bures, Maximilian; Höffler, Hans-Klaus; Friedel, Godehard; Kyriss, Thomas; Boedeker, Enole; Länger, Florian; Zardo, Patrick; Zhang, Ruoyu.
Afiliação
  • Bures M; Department of Cardiac, Thoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany.
  • Höffler HK; Department of Cardiac, Thoracic, Transplantation and Vascular Surgery, Hannover Medical School, Hannover, Germany.
  • Friedel G; Department of Thoracic Surgery, Center for Pneumology and Thoracic Surgery, Schillerhoehe Hospital, Teaching hospital of the University of Tuebingen, Solitudestr. 18, Gerlingen, Germany.
  • Kyriss T; Department of Thoracic Surgery, Center for Pneumology and Thoracic Surgery, Schillerhoehe Hospital, Teaching hospital of the University of Tuebingen, Solitudestr. 18, Gerlingen, Germany.
  • Boedeker E; Department of Thoracic Surgery, Center for Pneumology and Thoracic Surgery, Schillerhoehe Hospital, Teaching hospital of the University of Tuebingen, Solitudestr. 18, Gerlingen, Germany.
  • Länger F; Department of Pathology, Hannover Medical School, Hannover, Germany.
  • Zardo P; Department of Cardiac and Thoracic Surgery, Otto-von-Guericke University Magdeburg, Magdeburg, Germany.
  • Zhang R; Department of Thoracic Surgery, Center for Pneumology and Thoracic Surgery, Schillerhoehe Hospital, Teaching hospital of the University of Tuebingen, Solitudestr. 18, Gerlingen, Germany. zhang.ruoyu@yahoo.com.
J Cardiothorac Surg ; 11(1): 63, 2016 Apr 12.
Article em En | MEDLINE | ID: mdl-27072534
ABSTRACT

BACKGROUND:

Albumin-glutaraldehyde glue gained a widespread acceptance in repair of superficial lung defects associated with alveolar air leaks (AAL). As its sealing efficacy has not yet been thoroughly corroborated by clinical studies, we sought to assess the properties of commercially available albumin-glutaraldehyde glue (BioGlue™) in an in vitro lung model.

METHODS:

The lower lobe of freshly excised swine lung (n = 10) was intubated and ventilated. A focal superficial parenchymal defect (40 × 25 mm) was created on the inflated lung. AAL was assessed with increasing inspired tidal volume (TVi). After glue application, AAL was assessed until burst failure occurred. To evaluate glue elasticity, the length of defect was recorded in the inflated lung.

RESULTS:

Superficial parenchymal defects resulted in AAL increasing with ascending TVi. Multiple linear regression analysis revealed strong correlation between AAL and maximal inspiratory pressure. There was one application error. At TVi = 400, 500, 600, 700, 800 and 900 ml, BioGlue™ achieved complete sealing in nine, six, five, four two and one specimens, respectively. Mean burst pressure was 38.0 ± 4.2 cmH2O. All sealant failures were cohesive. BioGlue™ allowed an expansion of covered lung defects of 1.5 ± 1.7 mm.

CONCLUSIONS:

Our in vitro tests demonstrated a high sealing efficacy of BioGlue™ for repair of superficial lung defects. Due to the rigid nature, caution should be taken to use this kind of sealant in trapped lungs.