Your browser doesn't support javascript.
loading
Expanding preconception carrier screening for the Jewish population using high throughput microfluidics technology and next generation sequencing.
Gal, Moran; Khermesh, Khen; Barak, Michal; Lin, Min; Lahat, Hadas; Reznik Wolf, Haike; Lin, Michael; Pras, Elon; Levanon, Erez Y.
Afiliação
  • Gal M; The Mina and Everard Goodman Faculty of Life Sciences, Bar-Ilan University, Ramat Gan, 52900, Israel.
  • Khermesh K; The Mina and Everard Goodman Faculty of Life Sciences, Bar-Ilan University, Ramat Gan, 52900, Israel.
  • Barak M; The Mina and Everard Goodman Faculty of Life Sciences, Bar-Ilan University, Ramat Gan, 52900, Israel.
  • Lin M; Fluidigm corporation, South San Francisco, California.
  • Lahat H; The Danek Gertner Institute of Human Genetics, Sheba Medical Center, Tel Hashomer, Israel.
  • Reznik Wolf H; The Danek Gertner Institute of Human Genetics, Sheba Medical Center, Tel Hashomer, Israel.
  • Lin M; Fluidigm corporation, South San Francisco, California.
  • Pras E; The Danek Gertner Institute of Human Genetics, Sheba Medical Center, Tel Hashomer, Israel.
  • Levanon EY; Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv, Israel.
BMC Med Genomics ; 9(1): 24, 2016 05 13.
Article em En | MEDLINE | ID: mdl-27175728
BACKGROUND: Genetic screening to identify carriers of autosomal recessive diseases has become an integral part of routine prenatal care. In spite of the rapid growth of known mutations, most current screening programs include only a small subset of these mutations, and are performed using diverse molecular techniques, which are generally labor-intensive and time consuming. We examine the implementation of the combined high-throughput technologies of specific target amplification and next generation sequencing (NGS), for expanding the carrier screening program in the Israeli Jewish population as a test case. METHODS: We compiled a panel of 370 germline mutations, causing 120 disorders, previously identified in affected Jewish individuals from different ethnicities. This mutation panel was simultaneously captured in 48 samples using a multiplex PCR-based microfluidics approach followed by NGS, thereby performing 17,760 individual assays in a single experiment. RESULTS: The sensitivity (measured with depth of at least 50×) and specificity of the target capture was 98 and 95 % respectively, leaving minimal rate of inconclusive tests per sample tested. 97 % of the targeted mutations present in the samples were correctly identified and validated. CONCLUSION: Our methodology was shown to successfully combine multiplexing of target specific primers, samples indexing and NGS technology for population genetic screens. Moreover, it's relatively ease of use and flexibility of updating the targets screened, makes it highly suitable for clinical implementation. This protocol was demonstrated in pre-conceptional screening for pan-Jewish individuals, but can be applied to any other population or different sets of mutations.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Judeus / Testes Genéticos / Dispositivos Lab-On-A-Chip / Fertilização / Sequenciamento de Nucleotídeos em Larga Escala Tipo de estudo: Diagnostic_studies / Guideline / Screening_studies Limite: Humans Idioma: En Revista: BMC Med Genomics Assunto da revista: GENETICA MEDICA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Israel

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Judeus / Testes Genéticos / Dispositivos Lab-On-A-Chip / Fertilização / Sequenciamento de Nucleotídeos em Larga Escala Tipo de estudo: Diagnostic_studies / Guideline / Screening_studies Limite: Humans Idioma: En Revista: BMC Med Genomics Assunto da revista: GENETICA MEDICA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: Israel