[Effect of Paroxysmal Atrial Fibrillation on Parameters Monitored by Transpulmonary Thermodilution Method].
Zhu, Hua-dong; Zheng, Liang-liang; Li, Chen; Yao, Dong-qi; Liu, Ji-hai; Du, Tie-kuan; Yu, Xue-zhong; Xu, Jun.
Afiliação
  • Zhu HD; Department of Emergency Medicine,PUMC Hospital,CAMS and PUMC,Beijing 100730,China;
  • Zheng LL; Department of Emergency Medicine,PUMC Hospital,CAMS and PUMC,Beijing 100730,China;
  • Li C; Department of Emergency Medicine,PUMC Hospital,CAMS and PUMC,Beijing 100730,China;
  • Yao DQ; Department of Emergency Medicine,PUMC Hospital,CAMS and PUMC,Beijing 100730,China;
  • Liu JH; Department of Emergency Medicine,PUMC Hospital,CAMS and PUMC,Beijing 100730,China;
  • Du TK; Department of Emergency Medicine,PUMC Hospital,CAMS and PUMC,Beijing 100730,China;
  • Yu XZ; Department of Emergency Medicine,PUMC Hospital,CAMS and PUMC,Beijing 100730,China;
  • Xu J; Department of Emergency Medicine,PUMC Hospital,CAMS and PUMC,Beijing 100730,China;
Zhongguo Yi Xue Ke Xue Yuan Xue Bao ; 38(2): 140-3, 2016 Apr.
Article em Zh | MEDLINE | ID: mdl-27181888
ABSTRACT

OBJECTIVE:

To investigate the effect of atrial fibrillation on the accuracy of parameters monitored by transpulmonary thermodilution method.

METHODS:

Totally 12 patients from emergency intensive care unit with paroxysmal atrial fibrillation were enrolled. The hemodynamic parameters such as heart rate, mean arterial pressure, cardiac index, systemic vascular resistance index, intrathoracic blood volume index, and extravascular lung water index were monitored by transpulmonary thermodilution method before paroxysmal atrial fibrillation and during atrial fibrillation, the number of B-lines was detected by lung ultrasonography before and during paroxysmal atrial fibrillation. The changes of all the parameters were analyzed.

RESULTS:

When the paroxysmal atrial fibrillation happened, the heart rate increased significantly [(123.3±20.0) beat/min vs. (98.9±12.3) beat/min, P=0.006]; the mean arterial pressure [(86.9±10.2) mmHg vs. (93.0±12.5) mmHg, P=0.058], cardiac index [(2.82±0.62) L/(min·m(2)) vs. (3.31±1.02) L/(min·m(2)), P=0.058] and systemic vascular resistance index [(2254±947) dyn·s·cm(-5)·m(2) vs. (2302±828) dyn·s·cm(-5)·m(2), P=0.351] had no obvious change; however, the intrathoracic blood volume index significantly increased [(1333±90) ml/m(2) vs. (937±111) ml/m(2), P<0.001]; extravascular lung water index also increased significantly [(16.1±1.1) ml/kg vs. (6.5±1.9) ml/kg, P<0.001]. No significant difference was found in the number of B-lines detected by lung ultrasonography before and during atrial fibrillation (10.0±4.2 vs. 9.4±4.4, P=0.180).

CONCLUSION:

Both intrathoracic blood volume and extravascular lung water monitored by transpulmonary thermodilution method were overvalued during paroxysmal atrial fibrillation, which may mislead the clinical judgment and decision-making.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Termodiluição / Volume Sanguíneo / Água Extravascular Pulmonar Tipo de estudo: Prognostic_studies Limite: Humans Idioma: Zh Revista: Zhongguo Yi Xue Ke Xue Yuan Xue Bao Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fibrilação Atrial / Termodiluição / Volume Sanguíneo / Água Extravascular Pulmonar Tipo de estudo: Prognostic_studies Limite: Humans Idioma: Zh Revista: Zhongguo Yi Xue Ke Xue Yuan Xue Bao Ano de publicação: 2016 Tipo de documento: Article