Your browser doesn't support javascript.
loading
Patient-specific 3D models created by 3D imaging system or bi-planar imaging coupled with Moiré-Fringe projections: a comparative study of accuracy and reliability on spinal curvatures and vertebral rotation data.
Hocquelet, Arnaud; Cornelis, François; Jirot, Anna; Castaings, Laurent; de Sèze, Mathieu; Hauger, Olivier.
Afiliação
  • Hocquelet A; Service D'imagerie Ostéo-articulaire, Hopital Pellegrin, Place Amélie-Raba-Léon, 33076, Bordeaux, France.
  • Cornelis F; Service D'imagerie Ostéo-articulaire, Hopital Pellegrin, Place Amélie-Raba-Léon, 33076, Bordeaux, France. francois.cornelis@chu-bordeaux.fr.
  • Jirot A; Unité de Médecine Orthopédique, Service de MPR, Hôpital Tastet-Girard, Groupe Hospitalier Pellegrin, CHU de Bordeaux, Place Amélie-Raba-Léon, 33076, Bordeaux, France.
  • Castaings L; Service D'imagerie Ostéo-articulaire, Hopital Pellegrin, Place Amélie-Raba-Léon, 33076, Bordeaux, France.
  • de Sèze M; Unité de Médecine Orthopédique, Service de MPR, Hôpital Tastet-Girard, Groupe Hospitalier Pellegrin, CHU de Bordeaux, Place Amélie-Raba-Léon, 33076, Bordeaux, France.
  • Hauger O; Service D'imagerie Ostéo-articulaire, Hopital Pellegrin, Place Amélie-Raba-Léon, 33076, Bordeaux, France.
Eur Spine J ; 25(10): 3154-3161, 2016 10.
Article em En | MEDLINE | ID: mdl-27323963
ABSTRACT

PURPOSE:

The aim of this study is to compare the accuracy and reliability of spinal curvatures and vertebral rotation data based on patient-specific 3D models created by 3D imaging system or by bi-planar imaging coupled with Moiré-Fringe projections. METHODS AND MATERIALS Sixty-two consecutive patients from a single institution were prospectively included. For each patient, frontal and sagittal calibrated low-dose bi-planar X-rays were performed and coupled simultaneously with an optical Moiré back surface-based technology. The 3D reconstructions of spine and pelvis were performed independently by one radiologist and one technician in radiology using two different semi-automatic methods using 3D radio-imaging system (method 1) or bi-planar imaging coupled with Moiré projections (method 2). Both methods were compared using Bland-Altman analysis, and reliability using intraclass correlation coefficient (ICC).

RESULTS:

ICC showed good to very good agreement. Between the two techniques, the maximum 95 % prediction limits was -4.9° degrees for the measurements of spinal coronal curves and less than 5° for other parameters. Inter-rater reliability was excellent for all parameters across both methods, except for axial rotation with method 2 for which ICC was fair. Method 1 was faster for reconstruction time than method 2 for both readers (13.4 vs. 20.7 min and 10.6 vs. 13.9 min; p = 0.0001).

CONCLUSION:

While a lower accuracy was observed for the evaluation of the axial rotation, bi-planar imaging coupled with Moiré-Fringe projections may be an accurate and reliable tool to perform 3D reconstructions of the spine and pelvis.
Assuntos
Palavras-chave
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Escoliose / Radiografia / Imageamento Tridimensional Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Spine J Assunto da revista: ORTOPEDIA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: França
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Escoliose / Radiografia / Imageamento Tridimensional Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Spine J Assunto da revista: ORTOPEDIA Ano de publicação: 2016 Tipo de documento: Article País de afiliação: França