Your browser doesn't support javascript.
loading
Hard X-ray phase-contrast tomography of non-homogeneous specimens: grating interferometry versus propagation-based imaging.
Ruiz-Yaniz, Maite; Zanette, Irene; Sarapata, Adrian; Birnbacher, Lorenz; Marschner, Mathias; Chabior, Michael; Olbinado, Margie; Pfeiffer, Franz; Rack, Alexander.
Afiliação
  • Ruiz-Yaniz M; European Synchrotron Radiation Facility, 71 Rue des Martyrs, 38000 Grenoble, France.
  • Zanette I; Lehrstuhl für Biomedizinische Physik, Physik-Department and Institut für Medizintechnik, Technische Universität München, James-Franck-Strasse 1, 85748 Garching, Germany.
  • Sarapata A; Lehrstuhl für Biomedizinische Physik, Physik-Department and Institut für Medizintechnik, Technische Universität München, James-Franck-Strasse 1, 85748 Garching, Germany.
  • Birnbacher L; Lehrstuhl für Biomedizinische Physik, Physik-Department and Institut für Medizintechnik, Technische Universität München, James-Franck-Strasse 1, 85748 Garching, Germany.
  • Marschner M; Lehrstuhl für Biomedizinische Physik, Physik-Department and Institut für Medizintechnik, Technische Universität München, James-Franck-Strasse 1, 85748 Garching, Germany.
  • Chabior M; Lehrstuhl für Biomedizinische Physik, Physik-Department and Institut für Medizintechnik, Technische Universität München, James-Franck-Strasse 1, 85748 Garching, Germany.
  • Olbinado M; European Synchrotron Radiation Facility, 71 Rue des Martyrs, 38000 Grenoble, France.
  • Pfeiffer F; Lehrstuhl für Biomedizinische Physik, Physik-Department and Institut für Medizintechnik, Technische Universität München, James-Franck-Strasse 1, 85748 Garching, Germany.
  • Rack A; European Synchrotron Radiation Facility, 71 Rue des Martyrs, 38000 Grenoble, France.
J Synchrotron Radiat ; 23(Pt 5): 1202-9, 2016 09 01.
Article em En | MEDLINE | ID: mdl-27577776
ABSTRACT
X-ray phase-contrast imaging is an effective approach to drastically increase the contrast and sensitivity of microtomographic techniques. Numerous approaches to depict the real part of the complex-valued refractive index of a specimen are nowadays available. A comparative study using experimental data from grating-based interferometry and propagation-based phase contrast combined with single-distance phase retrieval applied to a non-homogeneous sample is presented (acquired at beamline ID19-ESRF). It is shown that grating-based interferometry can handle density gradients in a superior manner. The study underlines the complementarity of the two techniques for practical applications.