Your browser doesn't support javascript.
loading
Selective, switchable fluorescent probe for heparin based on aggregation-induced emission.
Wang, Yi Jia; Lin, Lei; Zhang, Xing; Schultz, Victor; Zhang, Fuming; Sun, Jing Zhi; Linhardt, Robert J.
Afiliação
  • Wang YJ; MoE Key Laboratory of Macromolecule Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310027, China; Department of Chemistry and Chemical Biology, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Tro
  • Lin L; Department of Chemistry and Chemical Biology, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY 12180, United States.
  • Zhang X; Department of Chemistry and Chemical Biology, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY 12180, United States.
  • Schultz V; Department of Chemistry and Chemical Biology, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY 12180, United States.
  • Zhang F; Department of Chemical and Biological Engineering, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY 12180, United States.
  • Sun JZ; MoE Key Laboratory of Macromolecule Synthesis and Functionalization, Department of Polymer Science and Engineering, Zhejiang University, Hangzhou 310027, China. Electronic address: sunjz@zju.edu.cn.
  • Linhardt RJ; Department of Chemistry and Chemical Biology, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY 12180, United States; Department of Biology, Center for Biotechnology and Interdisciplinary Studies, Rensselaer Polytechnic Institute, Troy, NY 12180, Unit
Anal Biochem ; 514: 48-54, 2016 12 01.
Article em En | MEDLINE | ID: mdl-27619488
A positively charged tetraphenylethene (TPE) derivative, TPE-4MN, was synthesized as a probe for heparin based on aggregation induced emission. On the addition of 5.0 µg/mL of heparin, TPE-4MN showed an enhanced emission of about 10-fold. The change in fluorescence at 475 nm was linear over a range of heparin concentrations of 0-1.0 µg/mL with an R = 0.99988 and the limit of detection (LOD) was calculated to be 0.75 µg/mL. The mechanism of the detection was proven to be through an ion pairing interaction. TPE-4MN showed good selectivity for heparin over other types of polysaccharides and could easily distinguish heparin from heparan sulfate, a glycosaminoglycan having a similar structure to that of heparin.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Heparina / Corantes Fluorescentes Idioma: En Revista: Anal Biochem Ano de publicação: 2016 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Heparina / Corantes Fluorescentes Idioma: En Revista: Anal Biochem Ano de publicação: 2016 Tipo de documento: Article