Your browser doesn't support javascript.
loading
Overlapping self-expandable metallic stent for palliation of a long (>10 cm) malignant gastroduodenal obstruction.
Tsauo, Jiaywei; Yoo, Moon-Won; Park, Jung-Hoon; Song, Ho-Young; Jun, Eun Jung; Cho, Young Chul; Kim, Guk Bae.
Afiliação
  • Tsauo J; 1 Departments of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Yoo MW; 2 Department of Surgery, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Park JH; 1 Departments of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Song HY; 3 Biomedical Engineering Center, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Jun EJ; 1 Departments of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Cho YC; 1 Departments of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
  • Kim GB; 1 Departments of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
Acta Radiol ; 58(5): 565-572, 2017 May.
Article em En | MEDLINE | ID: mdl-27687252
ABSTRACT
Background Self-expandable metallic stent (SEMS) placement is a well-established palliative treatment approach for malignant gastroduodenal obstruction. In patients with a long (>10 cm) stricture, multiple stents placed in an overlapping fashion are often required. Purpose To investigate the outcomes of overlapping SEMS placement for the palliative treatment of malignant gastroduodenal obstruction in patients with a long (>10 cm) stricture. Material and Methods The medical records of 40 patients who underwent fluoroscopic overlapping SEMS placement for malignant gastroduodenal obstruction due to a long (>10 cm) stricture were reviewed. Results The technical and clinical success rates were 100% and 65.0%, respectively. The mean length of the stricture was 17.0 ± 4.7 cm and the mean number of stents placed in each patient was 2.2 ± 0.5. Metastatic cancer (odds ratio [OR], 0.315; P = 0.018), Eastern Cooperative Oncology Group (ECOG) score ≥3 (OR, 0.018; P = 0.006), and carcinomatosis with ascites (OR, 0.025; P = 0.017) were independent predictors of poor clinical success. The rates of minor and major complications were 27.5% and 2.5%, respectively. The median stent patency and survival were 33 days (interquartile range [IQR], 19-60 days) and 35 days (IQR, 19-73 days), respectively. An ECOG score ≥3 was an independent predictor of a poor survival outcome (hazard ratio, 4.681; P < 0.001). Conclusion Overlapping SEMS placement may be safe and effective for the palliative treatment of malignant gastroduodenal obstruction in patients with a long (>10 cm) stricture.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cuidados Paliativos / Neoplasias Gástricas / Obstrução da Saída Gástrica / Stents Metálicos Autoexpansíveis Tipo de estudo: Observational_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Acta Radiol Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Cuidados Paliativos / Neoplasias Gástricas / Obstrução da Saída Gástrica / Stents Metálicos Autoexpansíveis Tipo de estudo: Observational_studies / Prognostic_studies Limite: Female / Humans / Male / Middle aged Idioma: En Revista: Acta Radiol Ano de publicação: 2017 Tipo de documento: Article