Your browser doesn't support javascript.
loading
N-Hydroxysuccinimide as an effective chemiluminescence coreactant for highly selective and sensitive detection.
Saqib, Muhammad; Li, Suping; Gao, Wenyue; Majeed, Saadat; Qi, Liming; Liu, Zhongyuan; Xu, Guobao.
Afiliação
  • Saqib M; State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, Jilin, 130022, People's Republic of China.
  • Li S; University of Chinese Academy of Sciences, Chinese Academy of Sciences, No. 19A Yuquanlu, Beijing, 100049, China.
  • Gao W; State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, Jilin, 130022, People's Republic of China.
  • Majeed S; State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, Jilin, 130022, People's Republic of China.
  • Qi L; University of Chinese Academy of Sciences, Chinese Academy of Sciences, No. 19A Yuquanlu, Beijing, 100049, China.
  • Liu Z; State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, Jilin, 130022, People's Republic of China.
  • Xu G; University of Chinese Academy of Sciences, Chinese Academy of Sciences, No. 19A Yuquanlu, Beijing, 100049, China.
Anal Bioanal Chem ; 408(30): 8851-8857, 2016 Dec.
Article em En | MEDLINE | ID: mdl-27738731
ABSTRACT
The development of novel coreactants for chemiluminescence is very important to improve performance and widen its applications without using any other catalyst. N-Hydroxysuccinimide (NHS), a highly popular amine-reactive, activating, or protecting reagent in biochemical applications and organic synthesis, has been explored as an efficient and stable chemiluminescence coreactant for the first time. The chemiluminescence intensity of the newly developed luminol-NHS system is about 22 times higher than that of the traditional luminol-H2O2 system. Chemiluminescence of this system is dramatically enhanced by Co2+. This new chemiluminescence system is then applied for the highly selective and ultrasensitive detection of Co2+ with limit of detection (0.01 nM) better than those of several conventional analytical methods. This system also enables the efficient detection of luminol (LOD = 7 pM) and NHS (LOD = 3.0 µM) with excellent sensitivity. This chemiluminescence method was then also utilized to detect Co2+ in tap water and blue silica gel with excellent recoveries in the range 99.20-103.07 %. This novel chemiluminescence system has several advantages, including simple, cost-effective, highly sensitive, selective, and wide linear range. We expect that this chemiluminescence system will be a promising candidate for chemical and biological sensing. Graphical Abstract Comparison of CL peak intensities of classical luminol-H2O2 CL system and newly developed luminol-NHS CL system.
Assuntos
Palavras-chave
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Succinimidas / Água Potável / Cobalto / Medições Luminescentes / Luminol Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2016 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Succinimidas / Água Potável / Cobalto / Medições Luminescentes / Luminol Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Anal Bioanal Chem Ano de publicação: 2016 Tipo de documento: Article