Your browser doesn't support javascript.
loading
Patients recall worse preoperative pain after shoulder arthroplasty than originally reported: a study of recall accuracy using the American Shoulder and Elbow Surgeons score.
Lowe, Jeremiah T; Li, Xinning; Fasulo, Sydney M; Testa, Edward J; Jawa, Andrew.
Afiliação
  • Lowe JT; New England Baptist Hospital, Boston, MA, USA; Boston Sports and Shoulder Center, Waltham, MA, USA.
  • Li X; Boston Medical Center, Boston, MA, USA.
  • Fasulo SM; New England Baptist Hospital, Boston, MA, USA; Boston Sports and Shoulder Center, Waltham, MA, USA.
  • Testa EJ; Tufts University School of Medicine, Boston, MA, USA.
  • Jawa A; New England Baptist Hospital, Boston, MA, USA; Boston Sports and Shoulder Center, Waltham, MA, USA. Electronic address: andrewjawa@gmail.com.
J Shoulder Elbow Surg ; 26(3): 506-511, 2017 Mar.
Article em En | MEDLINE | ID: mdl-27751719
ABSTRACT

BACKGROUND:

Patient-reported outcome measures (PROMs) are valuable tools for quantifying outcomes of orthopedic surgery. However, when baseline scores are not obtained, there is considerable controversy about whether PROMs can be administered retrospectively for patients to recall their preoperative state. We investigated the accuracy of patient recall after total shoulder arthroplasty (TSA) using the American Shoulder and Elbow Surgeons (ASES) assessment score.

METHODS:

Recalled ASES scores were collected postoperatively at 6 weeks, 3 months, 6 months, and 12 months from 169 patients who previously completed baseline scores before TSA. The ASES total score was divided into its two subcomponents functional ability and visual analog scale (VAS) for pain. We compared preoperative and recalled scores for each subcomponent and the total ASES score.

RESULTS:

Recalled ASES function scores were comparable to corresponding preoperative scores across all time points (analysis of variance, P = .21), but recalled VAS pain was significantly higher at all time points beyond 6 weeks after surgery (P = .0001 at 3 months; P = .005 at 6 months; and P = .001 at 12 months). As a result, the ASES total score was only comparable at 6 weeks after surgery (P = .39) and differed at all time points thereafter.

CONCLUSION:

Patients are able to recall preoperative function with considerable accuracy for up to 12 months after TSA. However, beyond 6 weeks postoperatively, patients recall having worse pain than they originally reported, and recalled ASES total scores are unreliable as a result.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Rememoração Mental / Dor de Ombro / Artroplastia do Ombro Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Shoulder Elbow Surg Assunto da revista: ORTOPEDIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Rememoração Mental / Dor de Ombro / Artroplastia do Ombro Limite: Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Shoulder Elbow Surg Assunto da revista: ORTOPEDIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos