Your browser doesn't support javascript.
loading
The Exeter Universal cemented femoral stem at 20 to 25 years: A report of 382 hips.
Petheram, T G; Whitehouse, S L; Kazi, H A; Hubble, M J W; Timperley, A J; Wilson, M J; Howell, J R.
Afiliação
  • Petheram TG; The Princess Elizabeth Orthopaedic Centre, Exeter EX2 5DW, UK.
  • Whitehouse SL; Queensland University of Technology, Brisbane, Queensland, Australia.
  • Kazi HA; The Princess Elizabeth Orthopaedic Centre, Exeter EX2 5DW, UK.
  • Hubble MJ; The Princess Elizabeth Orthopaedic Centre, Exeter EX2 5DW, UK.
  • Timperley AJ; The Princess Elizabeth Orthopaedic Centre, Exeter EX2 5DW, UK.
  • Wilson MJ; The Princess Elizabeth Orthopaedic Centre, Exeter EX2 5DW, UK.
  • Howell JR; The Princess Elizabeth Orthopaedic Centre, Exeter EX2 5DW, UK.
Bone Joint J ; 98-B(11): 1441-1449, 2016 Nov.
Article em En | MEDLINE | ID: mdl-27803218
AIMS: We present a minimum 20-year follow-up study of 382 cemented Exeter Universal total hip arthroplasties (350 patients) operated on at a mean age of 66.3 years (17 to 94). PATIENTS AND METHODS: All patients received the same design of femoral component, regardless of the original diagnosis. Previous surgery had been undertaken for 33 hips (8.6%). During the study period 218 patients with 236 hips (62%) died, 42 hips (11%) were revised and 110 hips (29%) in 96 patients were available for review. The acetabular components were varied and some designs are now obsolete, however they were all cemented. RESULTS: With an endpoint of revision for aseptic loosening or lysis, survivorship of the stem at 22.8 years was 99.0% (95% confidence interval (CI) 97.0 to 100). One stem was revised 21 years post-operatively in a patient with Gaucher's disease and proximal femoral osteolysis. Survivorship with aseptic loosening or lysis of the acetabular component or stem as the endpoint at 22.8 years was 89.3% (95% CI 84.8 to 93.8). With an endpoint of revision for any reason, overall survivorship was 82.9% (95% CI 77.4 to 88.4) at 22.8 years. Radiological review showed excellent preservation of bone stock at 20 to 25 years, and no impending failures of the stem. CONCLUSION: The Exeter femoral stem continues to perform well beyond 20 years. Cite this article: Bone Joint J 2016;98-B:1441-9.
Assuntos
Palavras-chave
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Prótese de Quadril Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Bone Joint J Ano de publicação: 2016 Tipo de documento: Article
Buscar no Google
Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Prótese de Quadril Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies Limite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Bone Joint J Ano de publicação: 2016 Tipo de documento: Article