A bioinspired ionic liquid tagged cobalt-salophen complex for nonenzymatic detection of glucose.
Benjamin, Michael; Manoj, Devaraj; Thenmozhi, Kathavarayan; Bhagat, Pundlik Rambhau; Saravanakumar, Duraisamy; Senthilkumar, Sellappan.
Afiliação
  • Benjamin M; Department of Chemistry, School of Advanced Sciences, VIT University, Vellore 632014, India.
  • Manoj D; Department of Chemistry, School of Advanced Sciences, VIT University, Vellore 632014, India.
  • Thenmozhi K; Department of Chemistry, School of Advanced Sciences, VIT University, Vellore 632014, India.
  • Bhagat PR; Department of Chemistry, School of Advanced Sciences, VIT University, Vellore 632014, India.
  • Saravanakumar D; Department of Chemistry, School of Advanced Sciences, VIT University, Vellore 632014, India. Electronic address: duraisarav@gmail.com.
  • Senthilkumar S; Department of Chemistry, School of Advanced Sciences, VIT University, Vellore 632014, India. Electronic address: senthilanalytical@gmail.com.
Biosens Bioelectron ; 91: 380-387, 2017 May 15.
Article em En | MEDLINE | ID: mdl-28061420
ABSTRACT
The development of efficient and cost effective nonenzymatic biosensors with remarkable sensitivity, selectivity and stability for the detection of biomolecules, especially glucose is one of the major challenges in materials- and electrochemistry. Herein, we report the design and preparation of nonenzymatic biosensor based on an ionic liquid tagged cobalt-salophen metal complex (Co-salophen-IL) immobilized on electrochemically reduced graphene oxide (ERGO) for the detection of glucose via an electrochemical oxidation. The bioinspired Co-salophen-IL complex has been synthesized and immobilized on ERGO, which was previously deposited on a screen printed carbon electrode (SPE) to form the Co-salophen-IL/ERGO/SPE nonenzymatic biosensor. The electrochemical behaviour of this modified electrode was studied using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Notably, the Co-salophen-IL/ERGO/SPE biosensor exhibited excellent electrocatalytic activity towards glucose oxidation in 0.1M NaOH, based on which an amperometric sensor has been developed. The modified electrode has shown prominent performance towards glucose detection over a wide linear range from 0.2µM to 1.8mM with a detection limit and sensitivity of 0.79µM and 62µAmM-1 respectively. The detection was carried out at 0.40V and such a less working potential excludes the interference from the coexisting oxidizable analytes. The role of Co-salophen, IL and ERGO in the electrocatalytic activity has been systematically investigated. Furthermore, the biosensor demonstrated high stability with good reproducibility.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Salicilatos / Cobalto / Líquidos Iônicos / Técnicas Eletroquímicas / Glucose / Grafite Tipo de estudo: Diagnostic_studies Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Índia

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Salicilatos / Cobalto / Líquidos Iônicos / Técnicas Eletroquímicas / Glucose / Grafite Tipo de estudo: Diagnostic_studies Idioma: En Revista: Biosens Bioelectron Assunto da revista: BIOTECNOLOGIA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Índia