Normative Values of Aortic Arch Structures in Premature Infants.
Dijkema, Elles J; Molenschot, Mirella C; Breur, Johannes M P J; de Vries, Willem B; Slieker, Martijn G.
Afiliação
  • Dijkema EJ; Department of Pediatric Cardiology, Wilhelmina Children's Hospital, University Medical Center Utrecht, Utrecht, The Netherlands. Electronic address: edijkema@umcutrecht.nl.
  • Molenschot MC; Department of Pediatric Cardiology, Wilhelmina Children's Hospital, University Medical Center Utrecht, Utrecht, The Netherlands.
  • Breur JM; Department of Pediatric Cardiology, Wilhelmina Children's Hospital, University Medical Center Utrecht, Utrecht, The Netherlands.
  • de Vries WB; Department of Neonatology, Wilhelmina Children's Hospital, University Medical Center Utrecht, Utrecht, The Netherlands.
  • Slieker MG; Department of Pediatric Cardiology, Wilhelmina Children's Hospital, University Medical Center Utrecht, Utrecht, The Netherlands.
J Am Soc Echocardiogr ; 30(3): 227-232, 2017 Mar.
Article em En | MEDLINE | ID: mdl-28139441
BACKGROUND: Aortic arch abnormalities represent 5% to 8% of all congenital heart disease. Measurements of the aortic arch dimensions on two-dimensional echocardiographic images remain of critical importance in the diagnosis of aortic arch pathology. To define aortic hypoplasia or coarctation, measured dimensions must be compared with normal values. Normal values have been described for children of all ages in earlier studies. However, normative data for premature infants are not yet available. Therefore, the aim of this study was to develop normative data in a cohort of premature infants, which could be used in the diagnosis of aortic arch abnormalities. METHODS: A single-center study was conducted in a large population of premature infants with gestational ages of ≤32 weeks without hemodynamically important congenital heart disease, chromosomal abnormalities, and/or major cerebral congenital malformations. Two-dimensional echocardiographic measurements of four aortic arch structures were made on the second, fourth, and sixth days after birth. RESULTS: Three hundred eighty-five preterm patients were included. No differences in dimensions were found among days 2, 4, and 6. The dimension of the isthmus showed no significant relation to the existence of a patent ductus arteriosus. Reference intervals with mean and SD were calculated across the range of birth weight. Regression analysis was performed with multiple determinants in different models. The best predictive value was found for birth weight in a cubic model. CONCLUSIONS: This work provides regression equations for the calculation of Z scores and reference intervals for aortic arch dimensions in a cohort of preterm infants born at gestational ages of ≤32 weeks. The normative data can be used in diagnosis and decision making involving aortic arch pathology in premature infants.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aorta Torácica / Recém-Nascido Prematuro / Ecocardiografia / Interpretação de Imagem Assistida por Computador Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Male / Newborn País/Região como assunto: Europa Idioma: En Revista: J Am Soc Echocardiogr Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Aorta Torácica / Recém-Nascido Prematuro / Ecocardiografia / Interpretação de Imagem Assistida por Computador Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Female / Humans / Male / Newborn País/Região como assunto: Europa Idioma: En Revista: J Am Soc Echocardiogr Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2017 Tipo de documento: Article