Long term effects of once-only flexible sigmoidoscopy screening after 17 years of follow-up: the UK Flexible Sigmoidoscopy Screening randomised controlled trial.
Lancet
; 389(10076): 1299-1311, 2017 04 01.
Article
em En
| MEDLINE
| ID: mdl-28236467
BACKGROUND: Colorectal cancer is the third most common cancer worldwide. Previous analyses have only reported follow-up after flexible sigmoidoscopy for a maximum of 12 years. We aimed to examine colorectal cancer incidence and mortality after a single flexible sigmoidoscopy screening and 17 years of follow-up. METHODS: In this multicentre randomised trial (UK Flexible Sigmoidoscopy Screening Trial), done between Nov 14, 1994, and March 30, 1999, 170â432 eligible men and women, who had indicated on a previous questionnaire that they would probably attend screening if invited, were randomly assigned (1:2) to an intervention group (offered flexible sigmoidoscopy screening) or a control group (not contacted). Randomisation was done centrally in blocks of 12, and stratified by trial centre, general practice, and household type. The nature of the intervention did not allow the staff to be masked to arm of the trial; however, randomisation was done in batches so that the control group and participants not yet randomised were unaware of their allocation status. The primary outcomes were incidence and mortality of colorectal cancer. Hazard ratios (HRs) and 95% CIs for colorectal cancer incidence and mortality were estimated for intention-to-treat and per-protocol analyses. The trial is registered with ISRCTN, number 28352761. FINDINGS: Our cohort analysis included 170â034 people: 112â936 in the control group and 57â098 in the intervention group, 40â621 (71%) of whom were screened and 16â477 (29%) were not screened. During screening and a median of 17·1 years' follow-up, colorectal cancer was diagnosed in 1230 individuals in the intervention group and 3253 in the control group, and 353 individuals in the intervention group versus 996 individuals in the control group died from colorectal cancer. In intention-to-treat analyses, colorectal cancer incidence was reduced by 26% (HR 0·74 [95% CI 0·70-0·80]; p<0·0001) in the intervention group versus the control group and colorectal cancer mortality was reduced by 30% (0·70 [0·62-0·79]; p<0·0001) in the intervention group versus the control group. In per-protocol analyses, adjusted for non-compliance, colorectal cancer incidence and mortality were 35% (HR 0·65 [95% CI 0·59-0·71]) and 41% (0·59 [0·49-0·70]) lower in the screened group. INTERPRETATION: A single flexible sigmoidoscopy continues to provide substantial protection from colorectal cancer diagnosis and death, with protection lasting at least 17 years. FUNDING: National Institute for Health Research Efficacy and Mechanism Evaluation.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Neoplasias Colorretais
/
Programas de Rastreamento
/
Sigmoidoscopia
/
Detecção Precoce de Câncer
Tipo de estudo:
Clinical_trials
/
Diagnostic_studies
/
Guideline
/
Incidence_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
/
Screening_studies
Limite:
Female
/
Humans
/
Male
/
Middle aged
País/Região como assunto:
Europa
Idioma:
En
Revista:
Lancet
Ano de publicação:
2017
Tipo de documento:
Article