Your browser doesn't support javascript.
loading
1H NMR at Larmor frequencies down to 3Hz by means of Field-Cycling techniques.
Kresse, B; Becher, M; Privalov, A F; Hofmann, M; Rössler, E A; Vogel, M; Fujara, F.
Afiliação
  • Kresse B; Institut für Festkörperphysik, TU Darmstadt, Hochschulstr. 6, 64289 Darmstadt, Germany. Electronic address: benjamin.kresse@physik.tu-darmstadt.de.
  • Becher M; Institut für Festkörperphysik, TU Darmstadt, Hochschulstr. 6, 64289 Darmstadt, Germany.
  • Privalov AF; Institut für Festkörperphysik, TU Darmstadt, Hochschulstr. 6, 64289 Darmstadt, Germany.
  • Hofmann M; Department of Chemistry, Louisiana State University, Baton Rouge, LA 70803, USA.
  • Rössler EA; Experimentalphysik II, Universität Bayreuth, 95440 Bayreuth, Germany.
  • Vogel M; Institut für Festkörperphysik, TU Darmstadt, Hochschulstr. 6, 64289 Darmstadt, Germany.
  • Fujara F; Institut für Festkörperphysik, TU Darmstadt, Hochschulstr. 6, 64289 Darmstadt, Germany.
J Magn Reson ; 277: 79-85, 2017 04.
Article em En | MEDLINE | ID: mdl-28258024
ABSTRACT
Field-Cycling (FC) NMR experiments were carried out at 1H Larmor frequencies down to about 3Hz. This could be achieved by fast switching a high polarizing magnetic field down to a low evolution field which is tilted with respect to the polarization field. Then, the low frequency Larmor precession of the nuclear spin magnetization about this evolution field is registered by means of FIDs in a high detection field. The crucial technical point of the experiment is the stabilization of the evolution field, which is achieved by compensating for temporal magnetic field fluctuations of all three spatial components. The paper reports on some other basic low field experiments such as the simultaneous measurement of the Larmor frequency and the spin-lattice relaxation time in such small fields as well as the irradiation of oscillating transversal magnetic field pulses at very low frequencies as a novel method for field calibration in low field FC NMR. The potential of low field FC is exemplified by the 1H relaxation dispersion of water at frequencies below about 2kHz stemming from the slow proton exchange process.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Magn Reson Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Magn Reson Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2017 Tipo de documento: Article