Characterization of succinimide stability during trypsin digestion for LC-MS analysis.
Nowak, Christine; Ponniah, Gomathinayagam; Neill, Alyssa; Liu, Hongcheng.
Afiliação
  • Nowak C; Product Characterization, Alexion Pharmaceuticals, 100 College Street, New Haven, CT 06510, United States.
  • Ponniah G; Product Characterization, Alexion Pharmaceuticals, 100 College Street, New Haven, CT 06510, United States.
  • Neill A; Product Characterization, Alexion Pharmaceuticals, 100 College Street, New Haven, CT 06510, United States.
  • Liu H; Product Characterization, Alexion Pharmaceuticals, 100 College Street, New Haven, CT 06510, United States. Electronic address: LiuH@alxn.com.
Anal Biochem ; 526: 1-8, 2017 06 01.
Article em En | MEDLINE | ID: mdl-28274724
LC-MS peptide mapping is the most commonly used method to analyze protein modifications. The proteins are generally digested using trypsin at a slightly basic pH at 37 °C from several hours to overnight. Assay-induced artifacts can be generated during this procedure, potentially causing false-positive or false-negative results for a given modification. Unfortunately, for the analysis of succinimide, both false-negative and false-positive results can be generated within the same procedure. This study evaluates the stability of succinimide during the peptide mapping procedure and has demonstrated that up to 13% of pre-existing succinimide was lost during a 4 h trypsin digestion at pH 5.0 which was previously determined to be optimal for the detection of succinimide. The same procedure was able to simultaneously generate approximately 3% succinimide. Using the optimized procedure, it was also found that two aspartate residues that are followed by glycine residues in the conserved Fc region of a recombinant monoclonal antibody were not prone to isomerization. On the other hand, an aspartate residue followed by a glycine in the heavy chain variable domain was highly susceptible to isomerization. Interestingly, the antibody containing the succinimide eluted from an SEC column after the monomer peak.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Succinimidas / Tripsina / Muramidase / Cromatografia Líquida Limite: Humans Idioma: En Revista: Anal Biochem Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Succinimidas / Tripsina / Muramidase / Cromatografia Líquida Limite: Humans Idioma: En Revista: Anal Biochem Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Estados Unidos