Accuracy in Blood Pressure Monitoring: The Effect of Noninvasive Blood Pressure Cuff Inflation on Intra-arterial Blood Pressure Values.
Sheshadri, Veena; Tiwari, Akhilesh Kumar; Nagappa, Mahesh; Venkatraghavan, Lashmi.
Afiliação
  • Sheshadri V; Department of Anesthesia, Toronto Western Hospital, Toronto, Canada.
  • Tiwari AK; Department of Anesthesia, Toronto Western Hospital, Toronto, Canada.
  • Nagappa M; Department of Anesthesia and Perioperative Medicine, University of Western Ontario, Ontario, Canada.
  • Venkatraghavan L; Department of Anesthesia, Toronto Western Hospital, Toronto, Canada.
Anesth Essays Res ; 11(1): 169-173, 2017.
Article em En | MEDLINE | ID: mdl-28298779
ABSTRACT
CONTEXT Both invasive and noninvasive blood pressure (invasive arterial blood pressure [IABP] and noninvasive BP [NIBP]) monitors are used perioperatively; however, they often produce different values. The reason for this discrepancy is not clear, and it is possible that the act of cuff inflation itself might affect the IABP values, especially with the recurrent cycling of NIBP cuff.

AIM:

The aim of this study was to determine the effect of ipsilateral NIBP cuff inflation on the contralateral IABP values. SETTINGS AND DESIGNS Prospective, observational study. MATERIALS AND

METHODS:

One hundred consecutive patients were studied. The NIBP device was set to cycle every 5 min for a total of 6 times. During each cuff inflation cycle, changes in IABP values from the arterial line in the contralateral arm were recorded. A total of 582 measurements were included for data analysis. STATISTICAL

ANALYSIS:

Chi-square, paired t-test, analysis of variance.

RESULTS:

Mean (± standard deviation) changes in systolic BP (SBP), diastolic BP, and mean BP with cuff inflation were 6.7 ± 5.9, 2.6 ± 4.0, and 4.0 ± 3.9 mmHg, respectively. We observed an increase of 0-10 mmHg in SBP in majority (73.4%) of cuff inflations. The changes in IABP did not differ between the patients with or without hypertension or with the baseline SBP.

CONCLUSIONS:

This study showed that there is a transient reactive rise in IABP values with NIBP cuff inflation. This is important information in the perioperative and intensive care settings, where both these measurement techniques are routinely used. The exact mechanism for this effect is not known but may be attributed to the pain and discomfort from cuff inflation.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies Idioma: En Revista: Anesth Essays Res Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Canadá

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Observational_studies Idioma: En Revista: Anesth Essays Res Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Canadá