Your browser doesn't support javascript.
loading
A simple metal staining procedure for identification and visualization of single cells by LA-ICP-MS.
Herrmann, A J; Techritz, S; Jakubowski, N; Haase, A; Luch, A; Panne, U; Mueller, L.
Afiliação
  • Herrmann AJ; Bundesanstalt für Materialforschung und -prüfung (BAM), Division 1.1 Inorganic Trace Analysis, Richard-Willstätter-Str. 11, 12489 Berlin, Germany. antje.hermann@bam.de and Humboldt-Universität zu Berlin, Department of Chemistry, Brook-Taylor-Str. 2, 12489 Berlin, Germany.
  • Techritz S; Bundesanstalt für Materialforschung und -prüfung (BAM), Division 1.1 Inorganic Trace Analysis, Richard-Willstätter-Str. 11, 12489 Berlin, Germany. antje.hermann@bam.de.
  • Jakubowski N; Bundesanstalt für Materialforschung und -prüfung (BAM), Division 1.1 Inorganic Trace Analysis, Richard-Willstätter-Str. 11, 12489 Berlin, Germany. antje.hermann@bam.de.
  • Haase A; Federal Institute for Risk Assessment, Department of Chemical and Product Safety, Max-Dohrn-Str. 8-10, 10589 Berlin, Germany.
  • Luch A; Federal Institute for Risk Assessment, Department of Chemical and Product Safety, Max-Dohrn-Str. 8-10, 10589 Berlin, Germany.
  • Panne U; Bundesanstalt für Materialforschung und -prüfung (BAM), Division 1.1 Inorganic Trace Analysis, Richard-Willstätter-Str. 11, 12489 Berlin, Germany. antje.hermann@bam.de and Humboldt-Universität zu Berlin, Department of Chemistry, Brook-Taylor-Str. 2, 12489 Berlin, Germany.
  • Mueller L; Bundesanstalt für Materialforschung und -prüfung (BAM), Division 1.1 Inorganic Trace Analysis, Richard-Willstätter-Str. 11, 12489 Berlin, Germany. antje.hermann@bam.de.
Analyst ; 142(10): 1703-1710, 2017 May 21.
Article em En | MEDLINE | ID: mdl-28396894
ABSTRACT
High lateral resolution of metal detection in single cells by use of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) demands powerful staining methods. In this work different staining procedures for the single cell analysis with LA-ICP-MS were optimized. An iridium intercalator was utilized to stain the cell nuclei whereas the whole cell was stained by the use of maleimido-mono-amide-DOTA (mDOTA) complexing lanthanide(iii) ions. The content of the artificially introduced metals per cell was quantified using a matrix matched calibration approach based on cellulose membranes onto which standards were spotted by a microarray spotter. Absolute metal stain amounts in the range of 2.34 to 9.81 femtomole per cell were determined. The metal staining procedures allow direct identification and visualization of single cells and their cell compartments by element microscopy without the use of bright field images of the sample.

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Analyst Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies Idioma: En Revista: Analyst Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Alemanha