Your browser doesn't support javascript.
loading
Cotransport of human adenoviruses with clay colloids and TiO2 nanoparticles in saturated porous media: Effect of flow velocity.
Syngouna, Vasiliki I; Chrysikopoulos, Constantinos V; Kokkinos, Petros; Tselepi, Maria A; Vantarakis, Apostolos.
Afiliação
  • Syngouna VI; School of Environmental Engineering, Technical University of Crete, 73100 Chania, Greece. Electronic address: vsyngouna@isc.tuc.gr.
  • Chrysikopoulos CV; School of Environmental Engineering, Technical University of Crete, 73100 Chania, Greece.
  • Kokkinos P; Environmental Microbiology Unit, Department of Public Health, University of Patras, 26500 Patras, Greece.
  • Tselepi MA; Environmental Microbiology Unit, Department of Public Health, University of Patras, 26500 Patras, Greece.
  • Vantarakis A; Environmental Microbiology Unit, Department of Public Health, University of Patras, 26500 Patras, Greece.
Sci Total Environ ; 598: 160-167, 2017 Nov 15.
Article em En | MEDLINE | ID: mdl-28441594
This study focuses on the effects of two clay colloids (kaolinite, KGa-1b and montmorillonite, STx-1b) and titanium dioxide (TiO2) nanoparticles (NPs) on human adenovirus transport and retention in water saturated porous media at three different pore water velocities (0.38, 0.74, and 1.21cm/min). Transport and cotransport experiments were performed in 30-cm long laboratory columns packed with clean glass beads with 2mm diameter. The experimental results suggested that the presence of KGa-1b, STx-1b and TiO2 NPs increased human adenovirus inactivation and attachment onto the solid matrix, due to the additional attachment sites available. Retention by the packed column was found to be highest (up to 99%) in the presence of TiO2 NPs at the highest pore water velocity, and lowest in the presence of KGa-1b. The experimental results suggested that adenoviruses would undergo substantial aggregation or heteroaggregation during cotransport. However, no distinct relationships between mass recoveries and water velocity could be established from the experimental cotransport data. Note that for the cotransport experiments, collision efficiency values were shown to be higher for the higher flow rate examined in this study.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Titânio / Adenovírus Humanos / Coloides / Nanopartículas Metálicas / Silicatos de Alumínio Idioma: En Revista: Sci Total Environ Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Titânio / Adenovírus Humanos / Coloides / Nanopartículas Metálicas / Silicatos de Alumínio Idioma: En Revista: Sci Total Environ Ano de publicação: 2017 Tipo de documento: Article