Your browser doesn't support javascript.
loading
A single-shot T2 mapping protocol based on echo-split gradient-spin-echo acquisition and parametric multiplexed sensitivity encoding based on projection onto convex sets reconstruction.
Chu, Mei-Lan; Chang, Hing-Chiu; Oshio, Koichi; Chen, Nan-Kuei.
Afiliação
  • Chu ML; Brain Imaging and Analysis Center, Duke University Medical Center, Durham, North Carolina, USA.
  • Chang HC; Department of Diagnostic Radiology, The University of Hong Kong, Hong Kong.
  • Oshio K; Department of Diagnostic Radiology, Keio University School of Medicine, Tokyo, Japan.
  • Chen NK; Brain Imaging and Analysis Center, Duke University Medical Center, Durham, North Carolina, USA.
Magn Reson Med ; 79(1): 383-393, 2018 Jan.
Article em En | MEDLINE | ID: mdl-28480603
PURPOSE: To develop a high-speed T2 mapping protocol that is capable of accurately measuring T2 relaxation time constants from a single-shot acquisition. THEORY: A new echo-split single-shot gradient-spin-echo (GRASE) pulse sequence is developed to acquire multicontrast data while suppressing signals from most nonprimary echo pathways in Carr-Purcell-Meiboom-Gill (CPMG) echoes. Residual nonprimary pathway signals are taken into consideration when performing T2 mapping using a parametric multiplexed sensitivity encoding based on projection onto convex sets (parametric-POCSMUSE) reconstruction method that incorporates extended phase graph modeling of GRASE signals. METHODS: The single-shot echo-split GRASE-based T2 mapping procedure was evaluated in human studies at 3 Tesla. The acquired data were compared with reference data obtained with a more time-consuming interleaved spin-echo echo planar imaging protocol. T2 maps derived from conventional single-shot GRASE scans, in which nonprimary echo pathways were not appropriately addressed, were also evaluated. RESULTS: Using the developed single-shot T2 mapping protocol, quantitatively accurate T2 maps can be obtained with a short scan time (<0.2 seconds per slice). CONCLUSION: Accurate T2 mapping with minimal signal contamination from CPMG high-order echo pathways can be achieved by the developed method that integrates single-shot echo-split GRASE acquisition and parametric-POCSMUSE reconstruction. Magn Reson Med 79:383-393, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador / Imagem Ecoplanar Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Interpretação de Imagem Assistida por Computador / Imagem Ecoplanar Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Humans Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Estados Unidos