A New Method for Blood NT-proBNP Determination Based on a Near-infrared Point of Care Testing Device with High Sensitivity and Wide Scope.
Zhang, Xiao Guang; Shu, Yao Gen; Gao, Ju; Wang, Xuan; Liu, Li Peng; Wang, Meng; Cao, Yu Xi; Zeng, Yi.
Afiliação
  • Zhang XG; National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China.
  • Shu YG; Beijing Runbio Biotechnology Development Co., Ltd, Beijing 100106, China.
  • Gao J; No.2 People's Hospital of Dali City, Dali 671003, Yunnan, China.
  • Wang X; Beijing Runbio Biotechnology Development Co., Ltd, Beijing 100106, China.
  • Liu LP; Beijing Runbio Biotechnology Development Co., Ltd, Beijing 100106, China.
  • Wang M; Department of Laboratory Medicine, Beijing Hospital, National Center of Gerontology, Beijing 100730, China.
  • Cao YX; National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China.
  • Zeng Y; National Institute for Viral Disease Control and Prevention, Chinese Center for Disease Control and Prevention, Beijing 102206, China.
Biomed Environ Sci ; 30(6): 426-431, 2017 Jun.
Article em En | MEDLINE | ID: mdl-28705266
OBJECTIVE: To develop a rapid, highly sensitive, and quantitative method for the detection of NT-proBNP levels based on a near-infrared point-of-care diagnostic (POCT) device with wide scope. METHODS: The lateral flow assay (LFA) strip of NT-proBNP was first prepared to achieve rapid detection. Then, the antibody pairs for NT-proBNP were screened and labeled with the near-infrared fluorescent dye Dylight-800. The capture antibody was fixed on a nitrocellulose membrane by a scribing device. Serial dilutions of serum samples were prepared using NT-proBNP-free serum series. The prepared test strips, combined with a near-infrared POCT device, were validated by known concentrations of clinical samples. The POCT device gave the output of the ratio of the intensity of the fluorescence signal of the detection line to that of the quality control line. The relationship between the ratio value and the concentration of the specimen was plotted as a work curve. The results of 62 clinical specimens obtained from our method were compared in parallel with those obtained from the Roche E411 kit. RESULTS: Based on the log-log plot, the new method demonstrated that there was a good linear relationship between the ratio value and NT-proBNP concentrations ranging from 20 pg/mL to 10 ng/mL. The results of the 62 clinical specimens measured by our method showed a good linear correlation with those measured by the Roche E411 kit. CONCLUSION: The new LFA detection method of NT-proBNP levels based on the near-infrared POCT device was rapid and highly sensitive with wide scope and was thus suitable for rapid and early clinical diagnosis of cardiac impairment.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fragmentos de Peptídeos / Fitas Reagentes / Imunoensaio / Peptídeo Natriurético Encefálico / Testes Imediatos / Cardiopatias / Raios Infravermelhos Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Biomed Environ Sci Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2017 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Fragmentos de Peptídeos / Fitas Reagentes / Imunoensaio / Peptídeo Natriurético Encefálico / Testes Imediatos / Cardiopatias / Raios Infravermelhos Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Revista: Biomed Environ Sci Assunto da revista: SAUDE AMBIENTAL Ano de publicação: 2017 Tipo de documento: Article País de afiliação: China