Forward treatment planning techniques to reduce the normalization effect in Gamma Knife radiosurgery.
Cheng, Hao-Wen; Lo, Wei-Lun; Kuo, Chun-Yuan; Su, Yu-Kai; Tsai, Jo-Ting; Lin, Jia-Wei; Wang, Yu-Jen; Pan, David Hung-Chi.
Afiliação
  • Cheng HW; Department of Radiation Oncology, Shuang Ho Hospital, Taipei Medical University, Taipei, Taiwan.
  • Lo WL; Gamma Knife Center, Shuang Ho Hospital, Taipei Medical University, Taipei, Taiwan.
  • Kuo CY; Department of Neurosurgery, Shuang Ho Hospital, Taipei Medical University, Taipei, Taiwan.
  • Su YK; Gamma Knife Center, Shuang Ho Hospital, Taipei Medical University, Taipei, Taiwan.
  • Tsai JT; Department of Surgery, School of Medicine, College of Medicine, Taipei Medical University, Taipei, Taiwan.
  • Lin JW; Department of Radiation Oncology, Shuang Ho Hospital, Taipei Medical University, Taipei, Taiwan.
  • Wang YJ; Department of Medical Imaging and Radiological Technology, Yuanpei University of Medical Technology, Hsinchu, Taiwan.
  • Pan DH; Department of Neurosurgery, Shuang Ho Hospital, Taipei Medical University, Taipei, Taiwan.
J Appl Clin Med Phys ; 18(6): 114-122, 2017 Nov.
Article em En | MEDLINE | ID: mdl-28960724
ABSTRACT
In Gamma Knife forward treatment planning, normalization effect may be observed when multiple shots are used for treating large lesions. This effect can reduce the proportion of coverage of high-value isodose lines within targets. The aim of this study was to evaluate the performance of forward treatment planning techniques using the Leksell Gamma Knife for the normalization effect reduction. We adjusted the shot positions and weightings to optimize the dose distribution and reduce the overlap of high-value isodose lines from each shot, thereby mitigating the normalization effect during treatment planning. The new collimation system, Leksell Gamma Knife Perfexion, which contains eight movable sectors, provides an additional means to reduce the normalization effect by using composite shots. We propose different techniques in forward treatment planning that can reduce the normalization effect. Reducing the normalization effect increases the coverage proportion of higher isodose lines within targets, making the high-dose region within targets more uniform and increasing the mean dose to targets. Because of the increase in the mean dose to the target after reducing the normalization effect, we can set the prescribed marginal dose at a higher isodose level and reduce the maximum dose, thereby lowering the risk of complications.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Planejamento de Assistência ao Paciente / Planejamento da Radioterapia Assistida por Computador / Neoplasias Encefálicas / Neuroma Acústico / Radiocirurgia Limite: Adult / Humans / Male / Middle aged Idioma: En Revista: J Appl Clin Med Phys Assunto da revista: BIOFISICA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Taiwan

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Planejamento de Assistência ao Paciente / Planejamento da Radioterapia Assistida por Computador / Neoplasias Encefálicas / Neuroma Acústico / Radiocirurgia Limite: Adult / Humans / Male / Middle aged Idioma: En Revista: J Appl Clin Med Phys Assunto da revista: BIOFISICA Ano de publicação: 2017 Tipo de documento: Article País de afiliação: Taiwan