Your browser doesn't support javascript.
loading
Physicochemical and surface properties of acrylic intraocular lenses and their clinical significance.
Jung, Gyeong Bok; Jin, Kyung-Hyun; Park, Hun-Kuk.
Afiliação
  • Jung GB; Department of Physics Education, Chosun University, 309 Pilmun-daero, Dong-gu Gwangju, 61452 Republic of Korea.
  • Jin KH; Department of Ophthalmology, College of Medicine, Kyung Hee University, Seoul, 02447 Republic of Korea.
  • Park HK; Department of Biomedical Engineering & Healthcare Industry Research Institute, College of Medicine, Kyung Hee University, 26 Kyungheedae-ro, Dongdaemun-gu Seoul, 02447 Republic of Korea.
J Pharm Investig ; 47(5): 453-460, 2017.
Article em En | MEDLINE | ID: mdl-29046825
To analyze and compare several commercially available acrylic intraocular lenses (IOLs) with particular regard to their clinical significance, we examined the physicochemical and surface properties of four currently available acrylic IOLs using static water contact angle, atomic force microscopy (AFM), Raman spectroscopy, and differential scanning calorimetry (DSC) measurements. The hydrophobic acrylic IOLs, ZA9003, and MA60BM, had contact angles ranging from 77.9° ± 0.65° to 84.4° ± 0.09°. The contact angles in the hydrophilic acrylic (970C) and heparin-surface-modified (HSM) hydrophilic acrylic IOLs (BioVue) were 61.8° ± 0.45° and 69.7° ± 0.76°, respectively. The roughness of the IOL optic surface differed depending on the type of IOL (p < 0.001). The surface roughness of BioVue had the lowest value: 5.87 ± 1.26 nm. This suggests that the BioVue IOL may lead to reduced cellular adhesion compared to the unmodified IOLs. All IOLs including those composed of acrylic optic materials from different manufacturers showed distinct Raman spectra peaks. The glass transition temperatures (Tg) for the hydrophobic acrylic IOLs were between 12.5 and 13.8 °C. These results suggest that the intraoperative and postoperative behavior of an IOL can be predicted. This information is also expected to contribute greatly to the industrial production of reliable biocompatible IOLs.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: J Pharm Investig Ano de publicação: 2017 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Revista: J Pharm Investig Ano de publicação: 2017 Tipo de documento: Article