Improving the selectivity and sensitivity for quantifying 8-α-hydroxy-mutilin in rabbit tissues by using basic mobile phases and negative ionization.
Tan, Aimin; Gu, Guifen; Gui, Xuan; Wu, Yanxin; Bolger, Gordon; Licollari, Albert; Fanaras, John C.
Afiliação
  • Tan A; Nucro-Technics, Scarborough, ON, Canada. Electronic address: aimintan@hotmail.com.
  • Gu G; Nucro-Technics, Scarborough, ON, Canada.
  • Gui X; Nucro-Technics, Scarborough, ON, Canada.
  • Wu Y; Nucro-Technics, Scarborough, ON, Canada.
  • Bolger G; Nucro-Technics, Scarborough, ON, Canada.
  • Licollari A; Nucro-Technics, Scarborough, ON, Canada.
  • Fanaras JC; Nucro-Technics, Scarborough, ON, Canada.
Article em En | MEDLINE | ID: mdl-29153999
ABSTRACT
Previously reported LC-MS methods for quantifying 8-α-hydroxy-mutilin (a marker residue of tiamulin) in tissues all used a pseudo MRM transition (from protonated molecular ion to protonated molecular ion, m/z 337→337) due to difficulties in finding a product ion, leading to suboptimal selectivity and sensitivity for detection. By using electrospray negative ionization in a basic medium, we, for the first time, found a highly selective and sensitive true MRM transition for 8-α-hydroxy-mutilin, m/z 335→179. With this newly found MRM transition and the use of pleuromutilin as the internal standard, a very sensitive, selective, and robust LC-MS/MS method has been developed and validated for quantifying 8-α-hydroxy-mutilin in rabbit tissues (muscle, liver, kidney, and fat). In comparison with the previously published methods, the selectivity and sensitivity were significantly improved. For the concentration range validated (0.2-10ppm or 0.2-10µg/g), the within-run and between-run accuracies (% bias) ranged from -5.0 to 3.1 and -4.9 to 3.0, respectively. The% CV ranged from 2.2 to 6.6 and 4.7 to 8.3 for within-run and between-run precisions, respectively. The validated method was successfully used to support two GLP tissue residue depletion studies in rabbits.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos Policíclicos / Resíduos de Praguicidas / Cromatografia Líquida / Espectrometria de Massas em Tandem / Cetonas Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Compostos Policíclicos / Resíduos de Praguicidas / Cromatografia Líquida / Espectrometria de Massas em Tandem / Cetonas Tipo de estudo: Diagnostic_studies / Prognostic_studies Limite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Assunto da revista: ENGENHARIA BIOMEDICA Ano de publicação: 2018 Tipo de documento: Article