Your browser doesn't support javascript.
loading
Estimating the arterial input function from dynamic contrast-enhanced MRI data with compensation for flow enhancement (II): Applications in spine diagnostics and assessment of crohn's disease.
van Schie, Jeroen J N; Lavini, Cristina; van Vliet, Lucas J; Kramer, Gem; Pieters-van den Bos, Indra; Marcus, J T; Stoker, Jaap; Vos, Frans M.
Afiliação
  • van Schie JJN; Quantitative Imaging Group, Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands.
  • Lavini C; Department of Radiology and Nuclear Medicine, Academic Medical Center, Amsterdam, The Netherlands.
  • van Vliet LJ; Quantitative Imaging Group, Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands.
  • Kramer G; Department of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, The Netherlands.
  • Pieters-van den Bos I; Department of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, The Netherlands.
  • Marcus JT; Department of Radiology and Nuclear Medicine, VU University Medical Center, Amsterdam, The Netherlands.
  • Stoker J; Department of Radiology and Nuclear Medicine, Academic Medical Center, Amsterdam, The Netherlands.
  • Vos FM; Quantitative Imaging Group, Department of Imaging Physics, Delft University of Technology, Delft, The Netherlands.
J Magn Reson Imaging ; 47(5): 1197-1204, 2018 05.
Article em En | MEDLINE | ID: mdl-29193469
ABSTRACT

BACKGROUND:

Pharmacokinetic (PK) models can describe microvascular density and integrity. An essential component of PK models is the arterial input function (AIF) representing the time-dependent concentration of contrast agent (CA) in the blood plasma supplied to a tissue. PURPOSE/

HYPOTHESIS:

To evaluate a novel method for subject-specific AIF estimation that takes inflow effects into account. STUDY TYPE Retrospective study.

SUBJECTS:

Thirteen clinical patients referred for spine-related complaints; 21 patients from a study into luminal Crohn's disease with known Crohn's Disease Endoscopic Index of Severity (CDEIS). FIELD STRENGTH/SEQUENCE Dynamic fast spoiled gradient echo (FSPGR) at 3T. ASSESSMENT A population-averaged AIF, AIFs derived from distally placed regions of interest (ROIs), and the new AIF method were applied. Tofts' PK model parameters (including vp and Ktrans ) obtained with the three AIFs were compared. In the Crohn's patients Ktrans was correlated to CDEIS. STATISTICAL TESTS The median values of the PK model parameters from the three methods were compared using a Mann-Whitney U-test. The associated variances were statistically assessed by the Brown-Forsythe test. Spearman's rank correlation coefficient was computed to test the correlation of Ktrans to CDEIS.

RESULTS:

The median vp was significantly larger when using the distal ROI approach, compared to the two other methods (P < 0.05 for both comparisons, in both applications). Also, the variances in vp were significantly larger with the ROI approach (P < 0.05 for all comparisons). In the Crohn's disease study, the estimated Ktrans parameter correlated better with the CDEIS (r = 0.733, P < 0.001) when the proposed AIF was used, compared to AIFs from the distal ROI method (r = 0.429, P = 0.067) or the population-averaged AIF (r = 0.567, P = 0.011). DATA

CONCLUSION:

The proposed method yielded realistic PK model parameters and improved the correlation of the Ktrans parameter with CDEIS, compared to existing approaches. LEVEL OF EVIDENCE 3 Technical Efficacy Stage 1 J. Magn. Reson. Imaging 2018;471197-1204.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artérias / Coluna Vertebral / Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética / Doença de Crohn / Meios de Contraste Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Holanda

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Artérias / Coluna Vertebral / Processamento de Imagem Assistida por Computador / Imageamento por Ressonância Magnética / Doença de Crohn / Meios de Contraste Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Limite: Humans Idioma: En Revista: J Magn Reson Imaging Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Holanda