Comparison of blood pressure monitoring by applanation tonometry and invasively assessed blood pressure in cardiological patients.
Greiwe, G; Hoffmann, S; Herich, L; Winkler, M S; Trepte, C J; Behem, C R; Petzoldt, M; Reuter, D A; Haas, S A.
Afiliação
  • Greiwe G; Department of Anaesthesiology, Centre of Anaesthesiology and Intensive Care Medicine, University Medical Centre Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany. g.greiwe@uke.de.
  • Hoffmann S; Department of Anaesthesiology, Centre of Anaesthesiology and Intensive Care Medicine, University Medical Centre Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
  • Herich L; Clinical Care and Management Innovation Research Area, Research Unit of Perinatal Epidemiology, Bambino Gesù Children's Hospital, Piazza di Sant'Onofrio 4, 00165, Rome, Italy.
  • Winkler MS; Department of Anaesthesiology, Centre of Anaesthesiology and Intensive Care Medicine, University Medical Centre Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
  • Trepte CJ; Department of Anaesthesiology, Centre of Anaesthesiology and Intensive Care Medicine, University Medical Centre Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
  • Behem CR; Department of Anaesthesiology, Centre of Anaesthesiology and Intensive Care Medicine, University Medical Centre Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
  • Petzoldt M; Department of Anaesthesiology, Centre of Anaesthesiology and Intensive Care Medicine, University Medical Centre Hamburg-Eppendorf, Martinistrasse 52, 20246, Hamburg, Germany.
  • Reuter DA; Department of Anaesthesia and Intensive Care Medicine, Rostock University Medical Centre, Schillingallee 35, 18057, Rostock, Germany.
  • Haas SA; Department of Anaesthesia and Intensive Care Medicine, Rostock University Medical Centre, Schillingallee 35, 18057, Rostock, Germany.
J Clin Monit Comput ; 32(5): 817-823, 2018 Oct.
Article em En | MEDLINE | ID: mdl-29204771
ABSTRACT
The aim of this study was to evaluate the accuracy and precision of non-invasive continuous blood pressure measurement by applanation tonometry (AT) in awake or anaesthetised cardiological intensive care patients. Patients suffering from highly impaired left ventricular function atrial fibrillation or severe aortic valve stenosis were included into the study. Arterial blood pressure was recorded by applanation tonometry (T-Line 400, Tensys Medical®, USA) and an arterial line in awake or anaesthetised patients. Discrepancies in mean (MAP), systolic (SAP), and diastolic (DAP) arterial pressure between the two methods were assessed as bias, limits of agreement and percentage error respectively. In 31 patients a total of 27,900 measurements were analyzed. The concordance correlation coefficient was 0.23, 0.45 and 0.06 for MAP, SAP and DAP, respectively. For all patients bias for MAPAT compared to MAPAL was 14.96 mmHg (SAPAT 4.51 mmHg; DAPAT 19.12 mmHg) with limits of agreement for MAPAT of 46.25 and - 16.33 mm Hg (SAPAT 48.00 and - 38.98 mmHg; DAPAT 50.12 and - 11.89 mmHg). Percentage error for MAPAT was 56.8% (42.7% for SAPAT; 75.2% for DAPAT). We conclude that the AT method is not reliable in ICU patients with severe cardiac comorbidities.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Determinação da Pressão Arterial / Monitorização Hemodinâmica / Manometria Tipo de estudo: Evaluation_studies / Observational_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Clin Monit Comput Assunto da revista: INFORMATICA MEDICA / MEDICINA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Alemanha

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Determinação da Pressão Arterial / Monitorização Hemodinâmica / Manometria Tipo de estudo: Evaluation_studies / Observational_studies Limite: Aged / Female / Humans / Male / Middle aged Idioma: En Revista: J Clin Monit Comput Assunto da revista: INFORMATICA MEDICA / MEDICINA Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Alemanha