A comparison of computer-assisted detection (CAD) programs for the identification of colorectal polyps: performance and sensitivity analysis, current limitations and practical tips for radiologists.
Clin Radiol
; 73(6): 593.e11-593.e18, 2018 06.
Article
em En
| MEDLINE
| ID: mdl-29602538
ABSTRACT
AIM:
To directly compare the accuracy and speed of analysis of two commercially available computer-assisted detection (CAD) programs in detecting colorectal polyps. MATERIALS ANDMETHOD:
In this retrospective single-centre study, patients who had colorectal polyps identified on computed tomography colonography (CTC) and subsequent lower gastrointestinal endoscopy, were analysed using two commercially available CAD programs (CAD1 and CAD2). Results were compared against endoscopy to ascertain sensitivity and positive predictive value (PPV) for colorectal polyps. Time taken for CAD analysis was also calculated.RESULTS:
CAD1 demonstrated a sensitivity of 89.8%, PPV of 17.6% and mean analysis time of 125.8 seconds. CAD2 demonstrated a sensitivity of 75.5%, PPV of 44.0% and mean analysis time of 84.6 seconds.CONCLUSION:
The sensitivity and PPV for colorectal polyps and CAD analysis times can vary widely between current commercially available CAD programs. There is still room for improvement. Generally, there is a trade-off between sensitivity and PPV, and so further developments should aim to optimise both. Information on these factors should be made routinely available, so that an informed choice on their use can be made. This information could also potentially influence the radiologist's use of CAD results.
Texto completo:
1
Coleções:
01-internacional
Base de dados:
MEDLINE
Assunto principal:
Pólipos Intestinais
Tipo de estudo:
Diagnostic_studies
/
Evaluation_studies
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Aged
/
Aged80
/
Humans
/
Middle aged
Idioma:
En
Revista:
Clin Radiol
Ano de publicação:
2018
Tipo de documento:
Article