Your browser doesn't support javascript.
loading
[Evaluation of the coagulometer STA R Max® (Stago) for routine coagulation parameters]. / Évaluation des performances de l'automate STA R Max® (Stago) pour les paramètres d'hémostase de routine.
Brulé, Justine; Sinegre, Thomas; Pereira, Bruno; Berger, Marc G; Serre-Sapin, Anne-Françoise; Lebreton, Aurélien.
Afiliação
  • Brulé J; Service d'hématologie biologique, CHU de Clermont-Ferrand, Hôpital Estaing, Clermont-Ferrand, France.
  • Sinegre T; Service d'hématologie biologique, CHU de Clermont-Ferrand, Hôpital Estaing, Clermont-Ferrand, France.
  • Pereira B; Unité de biostatistiques, Direction de la recherche clinique et de l'innovation, CHU Gabriel-Montpied, Clermont-Ferrand, France.
  • Berger MG; Service d'hématologie biologique, CHU de Clermont-Ferrand, Hôpital Estaing, Clermont-Ferrand, France.
  • Serre-Sapin AF; Service d'hématologie biologique, CHU de Clermont-Ferrand, Hôpital Estaing, Clermont-Ferrand, France.
  • Lebreton A; Service d'hématologie biologique, CHU de Clermont-Ferrand, Hôpital Estaing, Clermont-Ferrand, France.
Ann Biol Clin (Paris) ; 76(2): 143-149, 2018 04 01.
Article em Fr | MEDLINE | ID: mdl-29623883
The STA R Max® is a fully automated multiparameter coagulometer using clotting (viscosity-based detection system), chromogenic and immunologic assays. STA R Max® is equipped with an innovative software (STA Coag Expert®) designed to assist laboratory in accreditation. The aim of this study was to evaluate its performances for the certification according to ISO 15189 quality standard in the haemostasis unit of our university hospital. The following tests were evaluated: prothrombin time (PT), activated partial thromboplastin time (aPTT), kaolin cephalin clotting time (KCCT), fibrinogen, anti-Xa assay and D-dimers. In normal and pathological range, the intra-assay coefficients of variation (CV) for PT, aPTT, KCCT and fibrinogen were below 4.0%. Intra-assay CV was of 4.0% for the anti-Xa assay and intra-assay CV was of 7.9% for D-dimers. Inter-assay CV were below 5.0% for PT, aPPT, KCCT and fibrinogen, 14.9% for anti-Xa assay and 8.6% for D-dimers. The interlaboratory comparisons were below 8.7% for PT, aPPT and KCCT, 5.0% for fibrinogen and 15.5% for anti-Xa assay. All results were acceptable according to suitable CV established by GFHT and the provider. The concordance between all coagulometers was excellent, with correlation coefficient close to 1 (0.99 for all parameters except for aPPT which was 0.98) calculated thanks to an intra-class correlation study. In conclusion, the STA R Max® analyser is suitable for haemostasis laboratories and facilitates certification of a laboratory.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coagulação Sanguínea / Testes de Coagulação Sanguínea Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Humans País/Região como assunto: Europa Idioma: Fr Revista: Ann Biol Clin (Paris) Ano de publicação: 2018 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Coagulação Sanguínea / Testes de Coagulação Sanguínea Tipo de estudo: Diagnostic_studies / Evaluation_studies Limite: Humans País/Região como assunto: Europa Idioma: Fr Revista: Ann Biol Clin (Paris) Ano de publicação: 2018 Tipo de documento: Article País de afiliação: França