Green and fast determination of the alcoholic content of wines using thermal infrared enthalpimetry.
Oliveira, Alessandra S; Ballus, Cristiano A; Menezes, Cristiano R; Wagner, Roger; Paniz, José Neri G; Tischer, Bruna; Costa, Adilson B; Barin, Juliano S.
Afiliação
  • Oliveira AS; Departamento de Tecnologia e Ciência dos Alimentos, Universidade Federal de Santa Maria, 97105-900 Santa Maria, RS, Brazil.
  • Ballus CA; Departamento de Tecnologia e Ciência dos Alimentos, Universidade Federal de Santa Maria, 97105-900 Santa Maria, RS, Brazil.
  • Menezes CR; Departamento de Tecnologia e Ciência dos Alimentos, Universidade Federal de Santa Maria, 97105-900 Santa Maria, RS, Brazil.
  • Wagner R; Departamento de Tecnologia e Ciência dos Alimentos, Universidade Federal de Santa Maria, 97105-900 Santa Maria, RS, Brazil.
  • Paniz JNG; Departamento de Química, Universidade Federal de Santa Maria, 97105-900 Santa Maria, RS, Brazil.
  • Tischer B; Departamento de Tecnologia e Ciência dos Alimentos, Universidade Federal de Santa Maria, 97105-900 Santa Maria, RS, Brazil; Programa de Pós-Graduação em Sistemas e Processos Industriais, Universidade de Santa Cruz do Sul, 96815-900 Santa Cruz do Sul, RS, Brazil.
  • Costa AB; Programa de Pós-Graduação em Tecnologia Ambiental, Universidade de Santa Cruz do Sul, 96815-900 Santa Cruz do Sul, RS, Brazil; Programa de Pós-Graduação em Sistemas e Processos Industriais, Universidade de Santa Cruz do Sul, 96815-900 Santa Cruz do Sul, RS, Brazil.
  • Barin JS; Departamento de Tecnologia e Ciência dos Alimentos, Universidade Federal de Santa Maria, 97105-900 Santa Maria, RS, Brazil. Electronic address: juliano@ufsm.br.
Food Chem ; 258: 59-62, 2018 Aug 30.
Article em En | MEDLINE | ID: mdl-29655754
ABSTRACT
An innovative use of thermal infrared enthalpimetry (TIE) is proposed for the determination of alcoholic content of red and white wines. Notwithstanding the presence of ethanol in beverages, absolute ethanol was added directly to wines, and the temperature rise caused by the heat of dilution was monitored using an infrared camera. Analytical signals were obtained in only 10 s for four samples simultaneously, and a calibration curve was constructed with hydroalcoholic reference solutions. A linear calibration curve was obtained from 3.0 to 18.0% (v/v) ethanol (R2 = 0.9987). The results showed agreement ranging from 98.2 to 104.0% with 942.06 and 969.12 methods of AOAC. Organic compounds (e.g., sugar) did not interfere in the determinations. The proposed method provided fast results, with a throughput of 480 samples per hour and negligible energy consumption (0.001 kWh). In addition, the consumption of reagents was reduced when compared with conventional method fulfilling green analytical chemistry requirements.