Fast magnetic resonance fingerprinting for dynamic contrast-enhanced studies in mice.
Gu, Yuning; Wang, Charlie Y; Anderson, Christian E; Liu, Yuchi; Hu, He; Johansen, Mette L; Ma, Dan; Jiang, Yun; Ramos-Estebanez, Ciro; Brady-Kalnay, Susann; Griswold, Mark A; Flask, Chris A; Yu, Xin.
Afiliação
  • Gu Y; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio.
  • Wang CY; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio.
  • Anderson CE; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio.
  • Liu Y; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio.
  • Hu H; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio.
  • Johansen ML; Department of Molecular Biology and Microbiology, Case Western Reserve University, Cleveland, Ohio.
  • Ma D; Department of Radiology, Case Western Reserve University, Cleveland, Ohio.
  • Jiang Y; Department of Radiology, Case Western Reserve University, Cleveland, Ohio.
  • Ramos-Estebanez C; Department of Neurology, Case Western Reserve University, Cleveland, Ohio.
  • Brady-Kalnay S; Department of Radiology, Case Western Reserve University, Cleveland, Ohio.
  • Griswold MA; Department of Neurosciences, Case Western Reserve University, Cleveland, Ohio.
  • Flask CA; Department of Biomedical Engineering, Case Western Reserve University, Cleveland, Ohio.
  • Yu X; Department of Radiology, Case Western Reserve University, Cleveland, Ohio.
Magn Reson Med ; 80(6): 2681-2690, 2018 12.
Article em En | MEDLINE | ID: mdl-29744935
ABSTRACT

PURPOSE:

The goal of this study was to develop a fast MR fingerprinting (MRF) method for simultaneous T1 and T2 mapping in DCE-MRI studies in mice.

METHODS:

The MRF sequences based on balanced SSFP and fast imaging with steady-state precession were implemented and evaluated on a 7T preclinical scanner. The readout used a zeroth-moment-compensated variable-density spiral trajectory that fully sampled the entire k-space and the inner 10 × 10 k-space with 48 and 4 interleaves, respectively. In vitro and in vivo studies of mouse brain were performed to evaluate the accuracy of MRF measurements with both fully sampled and undersampled data. The application of MRF to dynamic T1 and T2 mapping in DCE-MRI studies were demonstrated in a mouse model of heterotopic glioblastoma using gadolinium-based and dysprosium-based contrast agents.

RESULTS:

The T1 and T2 measurements in phantom showed strong agreement between the MRF and the conventional methods. The MRF with spiral encoding allowed up to 8-fold undersampling without loss of measurement accuracy. This enabled simultaneous T1 and T2 mapping with 2-minute temporal resolution in DCE-MRI studies.

CONCLUSION:

Magnetic resonance fingerprinting provides the opportunity for dynamic quantification of contrast agent distribution in preclinical tumor models on high-field MRI scanners.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Meios de Contraste Tipo de estudo: Prognostic_studies Limite: Animals / Humans Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2018 Tipo de documento: Article

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Meios de Contraste Tipo de estudo: Prognostic_studies Limite: Animals / Humans Idioma: En Revista: Magn Reson Med Assunto da revista: DIAGNOSTICO POR IMAGEM Ano de publicação: 2018 Tipo de documento: Article