Your browser doesn't support javascript.
loading
Validation of an LC-MS/MS method for simultaneous determination of icotinib and its four major circulating metabolites in human plasma and its application in a pharmacokinetic study.
Xiao, Ying; Maiolino, Piera; Yan, Jin-Hua; Ma, Jie; Li, Jin; Chen, Li.
Afiliação
  • Xiao Y; Department of Pharmacy, The Third Hospital of Nanchang, Nanchang, Jiangxi, China.
  • Maiolino P; Department of Pharmacy, Institute National Tumour Fundation G. Pascale (IRCCS), Naples, Italy.
  • Yan JH; Department of Hematology, The Third Affiliated Hospital of Nanchang University, Nanchang, Jiangxi, China.
  • Ma J; Department of Galactophore, Jingzhou Central Hospital, Jingzhou, Hubei, China.
  • Li J; Department of Oncology, The First Huaian Hospital Affiliated Nanjing Medical University, Huaian, Jiangsu, China.
  • Chen L; Department of Pharmacy, The Third Hospital of Nanchang, Nanchang, Jiangxi, China.
Biomed Chromatogr ; 32(11): e4327, 2018 Nov.
Article em En | MEDLINE | ID: mdl-29975793
ABSTRACT
In this study, a simple and sensitive LC-MS/MS method was developed and validated for simultaneous determination of icotinib and its four circulating metabolites in human plasma. The analytes were extracted with acetonitrile and separated on a C18 column using 2 mm ammonium acetate containing 0.2% formic acid and acetonitrile as mobile phase. The analytes were introduced into the mass spectrometer via an electrospray ionization source operated in positive ion mode. Precursor-to-product transitions were optimized to be m/z 392.2 → 304.1 for icotinib, m/z 424.1 → 278.2 for M1 and M2, m/z 408.2 → 320.1 for M3, m/z 410.2 → 322.1 for M4 and m/z 394.4 → 278.1 for IS. The assay showed good linearity over the concentration ranges of 0.1-600 ng/mL for icotinib and 0.1-200 ng/mL for metabolites, with correlation coefficients >0.994 (r > 0.994). The LLOQ was 0.1 ng/mL for each analyte. The intra- and inter-day precisions (RSD) were ≤12.98% while the accuracy (RE) ranged from -8.76 to 12.01%. No significant matrix effect was observed. The validated method was successfully applied for the pharmacokinetic study of icotinib and its four circulating metabolites in human plasma after oral administration of icotinib at a single dose of 125 mg.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Quinazolinas / Cromatografia Líquida / Éteres de Coroa / Espectrometria de Massas em Tandem Tipo de estudo: Prognostic_studies Limite: Adult / Humans / Middle aged Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Quinazolinas / Cromatografia Líquida / Éteres de Coroa / Espectrometria de Massas em Tandem Tipo de estudo: Prognostic_studies Limite: Adult / Humans / Middle aged Idioma: En Revista: Biomed Chromatogr Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China