Discriminative and Quantitative Analysis of Antineoplastic Taxane Drugs Using a Handheld Raman Spectrometer.
Lê, Laetitia; Berge, Marion; Tfayli, Ali; Prognon, Patrice; Caudron, Eric.
Afiliação
  • Lê L; U-Psud, Univ. Paris-Saclay, Lip(Sys), EA7357, UFR-Pharmacy, Châtenay-Malabry, France.
  • Berge M; European Georges Pompidou Hospital (AP-HP), Pharmacy Department, Paris, France.
  • Tfayli A; European Georges Pompidou Hospital (AP-HP), Pharmacy Department, Paris, France.
  • Prognon P; U-Psud, Univ. Paris-Saclay, Lip(Sys), EA7357, UFR-Pharmacy, Châtenay-Malabry, France.
  • Caudron E; U-Psud, Univ. Paris-Saclay, Lip(Sys), EA7357, UFR-Pharmacy, Châtenay-Malabry, France.
Biomed Res Int ; 2018: 8746729, 2018.
Article em En | MEDLINE | ID: mdl-30065947
ABSTRACT
This study was conducted to evaluate the ability of Raman spectroscopy (RS) to control antineoplastic preparations used for chemotherapy in order to ensure its physical and chemical qualities. Three taxane drugs cabazitaxel (CBX), docetaxel (DCX) and paclitaxel (PCX) at therapeutic concentration ranges were analyzed using a handheld spectrometer at 785 nm. Qualitative and quantitative models were developed and optimized using a calibration set (n=75 per drug) by partial least square discriminant analysis and regression and validated using a test set (n=27 per drug). All samples were correctly assigned with an accuracy of 100%. Despite optimization, quantitative analysis showed limited performances at the lowest concentrations. The root mean square error of predictions ranged from 0.012 mg/mL for CBX to 0.048 mg/mL for DCX with a minimal coefficient of determination of 0.9598. The linearity range was validated from 0.175 to 0.30 mg/mL for CBX, from 0.40 to 1.00 mg/mL for DCX and from 0.57 to 1.20 mg/mL for PCX. Despite some limitations, this study confirms the potential of RS to control these drugs and also provides substantial advantages to secure the activity for healthcare workers. As a result of its rapidity and the uncomplicated use of a handheld instrument, RS appears to be a promising method to augment security of the medication preparation process in hospitals.
Assuntos

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise Espectral Raman / Taxoides / Antineoplásicos Tipo de estudo: Prognostic_studies / Qualitative_research Limite: Humans Idioma: En Revista: Biomed Res Int Ano de publicação: 2018 Tipo de documento: Article País de afiliação: França

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Análise Espectral Raman / Taxoides / Antineoplásicos Tipo de estudo: Prognostic_studies / Qualitative_research Limite: Humans Idioma: En Revista: Biomed Res Int Ano de publicação: 2018 Tipo de documento: Article País de afiliação: França