Your browser doesn't support javascript.
loading
Axial and shear pullout forces of composite, porcine and human metatarsal and cuboid bones.
Lenz, Mark; Gueorguiev, Boyko; Garces, Juan B Gerstner; Swords, Michael P; Rammelt, Stefan; Hofmann, Gunther O; Zderic, Ivan; Ernst, Manuela; Richards, Robert Geoff; Sands, Andrew K.
Afiliação
  • Lenz M; AO Research Institute Davos, Clavadelerstrasse 8, CH-7270 Davos-Platz, Switzerland.
  • Gueorguiev B; Dept. of Trauma, Hand and Reconstructive Surgery, University Hospital Jena, Am Klinikum 1, D-07747 Jena, Germany.
  • Garces JBG; AO Research Institute Davos, Clavadelerstrasse 8, CH-7270 Davos-Platz, Switzerland.
  • Swords MP; Centro Medico Imbanaco of Cali, Carrera 38 A, No. 5 A 100 Con 233, Cali, Colombia.
  • Rammelt S; Mid-Michigan Orthopaedic Institute, 830 West Lakee Lansing Road Suite 190, East Lansing, MI 48823, USA.
  • Hofmann GO; University Hospital Carl Gustav Carus, Fetscherstrasse 74, 01307 Dresden, Germany.
  • Zderic I; Dept. of Trauma, Hand and Reconstructive Surgery, University Hospital Jena, Am Klinikum 1, D-07747 Jena, Germany.
  • Ernst M; AO Research Institute Davos, Clavadelerstrasse 8, CH-7270 Davos-Platz, Switzerland.
  • Richards RG; AO Research Institute Davos, Clavadelerstrasse 8, CH-7270 Davos-Platz, Switzerland.
  • Sands AK; AO Research Institute Davos, Clavadelerstrasse 8, CH-7270 Davos-Platz, Switzerland.
J Orthop Translat ; 14: 67-73, 2018 Jul.
Article em En | MEDLINE | ID: mdl-30094182
OBJECTIVES: The varying mechanical properties of human bone have influence on the study results. Pullout and shear forces of human bone were compared to different substitutes to evaluate their suitability for biomechanical studies. METHODS: After bone mineral density (BMD) determination, axial pullout tests were performed with cortical 3.5 mm nonlocking (NL) and 2.7 mm head locking (HL) screws on human, porcine and polyurethane composite bones. Porcine and human constructs were additionally loaded in shear direction. RESULTS: Apparent BMD was significantly lower in osteoporotic (159 mgHA/ccm ± 56) and nonosteoporotic (229 mgHA/ccm ± 25) human bone than that in porcine bone (325 mgHA/ccm ± 42; p < 0.01). Axial construct stiffness and ultimate pullout force of porcine bone (NL: 666N/mm ± 226, 910N ± 140; HL: 309N/mm ± 88, 744N ± 185) was significantly different from composite bone (NL: 1284N/mm ± 161; 1175N ± 116; HL: 1241N/mm ± 172, 1185N ± 225) and osteoporotic human bone (NL: 204N/mm ± 121, 185N ± 113; HL: 201N/mm ± 65; 189N ± 58) but not from nonosteoporotic human bone (NL: 620N/mm ± 205, 852N ± 281; HL: 399N/mm ± 224; 567N ± 242). Porcine bone exhibited an ultimate shear force (NL: 278N ± 99; HL: 431N ± 155) comparable to nonosteoporotic human bone (NL: 207 ± 68: HL: 374N ± 137). CONCLUSION: Screw pullout and shear forces of porcine bone are close to nonosteoporotic human bone. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: Human bone specimens used in biomechanical studies are predominantly of osteoporotic bone quality. Conclusions on nonosteoporotic human bone behaviour are difficult. Alternatives such as porcine bone and composite bone were investigated, and it could be shown that screw pullout and screw shear forces of porcine bone are close to nonosteoporotic human bone.
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Orthop Translat Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Suíça

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Idioma: En Revista: J Orthop Translat Ano de publicação: 2018 Tipo de documento: Article País de afiliação: Suíça