Your browser doesn't support javascript.
loading
[Rapid determination of 48 contaminant residues in food contact plastic products by ultra performance liquid chromatography-quadrupole/electrostatic field orbitrap high resolution mass spectrometry coupled with microwave-assisted extraction].
Zhang, Xianchen; Zhang, Pengjie; Shi, Chengyu; Hua, Hongbo; Rong, Yutang; Lu, Junwen; Yang, Fang.
Afiliação
  • Zhang X; Inspection and Quarantine Technology Center of Zhongshan Entry-Exit Inspection and Quarantine Bureau, Zhongshan 528403, China.
  • Zhang P; Inspection and Quarantine Technology Center of Zhongshan Entry-Exit Inspection and Quarantine Bureau, Zhongshan 528403, China.
  • Shi C; Inspection and Quarantine Technology Center of Zhongshan Entry-Exit Inspection and Quarantine Bureau, Zhongshan 528403, China.
  • Hua H; Zhongshan Zhuoya Foreign Language School, Zhongshan 528401, China.
  • Rong Y; Inspection and Quarantine Technology Center of Zhongshan Entry-Exit Inspection and Quarantine Bureau, Zhongshan 528403, China.
  • Lu J; Inspection and Quarantine Technology Center of Zhongshan Entry-Exit Inspection and Quarantine Bureau, Zhongshan 528403, China.
  • Yang F; Inspection and Quarantine Technology Center of Zhongshan Entry-Exit Inspection and Quarantine Bureau, Zhongshan 528403, China.
Se Pu ; 36(7): 634-642, 2018 Jul 08.
Article em Zh | MEDLINE | ID: mdl-30136535
ABSTRACT
An ultra performance liquid chromatography-quadrupole/electrostatic field orbitrap high resolution mass spectrometry (UPLC-Q Orbitrap HRMS) method was developed for the rapid determination of 48 contaminant residues in food plastic packaging materials. The samples were extracted with methanol using microwave-assisted extraction. The separation of the 48 contaminants was performed on a CAPCELL PAK MG Ⅱ C18 column (150 mm×2.0 mm, 5 µm) with gradient elution. Methanol (containing 0.04% (v/v) formic acid) and water (containing 0.04% (v/v) formic acid and 20 mmol/L ammonium acetate) were used as mobile phases. The compounds were detected under the full scan/date dependent-MS/MS (Full MS/dd-MS2) mode with a heated electrospray ionization (HESI) source. The calibration curves were linear with correlation coefficients no less than 0.9950. The limits of detection (LODs) ranged from 0.1 to 1.0 µg/kg. The average spiked recoveries of the 48 target compounds were between 71.2% and 108.8%, with relative standard derivations (RSDs) ranging from 2.2% to 11.8% (n=6). Compared to previous methods, this method has advantages of simpler sample preparation and higher sensitivity.
Assuntos
Palavras-chave

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Plásticos / Contaminação de Alimentos / Embalagem de Alimentos Idioma: Zh Revista: Se Pu Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China

Texto completo: 1 Coleções: 01-internacional Base de dados: MEDLINE Assunto principal: Plásticos / Contaminação de Alimentos / Embalagem de Alimentos Idioma: Zh Revista: Se Pu Ano de publicação: 2018 Tipo de documento: Article País de afiliação: China